Jenn-Air G18Y07P-02 ユーザーズマニュアル

ページ / 34
 
 
11 
 
3.  Detach the regulator assembly from the tank 
valve by turning the quick coupling nut 
counterclockwise. 
4.  Place the dust cap on the liquid propane 
cylinder valve outlet when the cylinder is not in 
use. Only install the type of dust cap that is 
provided with the cylinder valve. The use of 
other caps or plugs may result in propane 
leakage. 
 
 
 
 
 
GENERAL 
Although gas connections on the grill are leak 
tested prior to shipment, a complete gas tightness 
check must be performed at the installation site. 
Before each use check the whole system for leaks 
following the procedures listed below.  
 
If the smell of gas is detected at anytime, you 
should immediately check the entire system for 
leaks. 
 
BEFORE TESTING
 
Make sure all packing materials have been 
removed from the grill, including the burner tie-
down straps. 
 
 WARNING 
Check all gas supply fittings for leaks before each 
use
Do not use the grill until all connections have 
been checked and do not leak.  
 
Do not smoke while leak testing. 
 
Never leak test with an open flame.  
Make a solution of one part liquid detergent and 
one part water. You will need a spray bottle, brush, 
or rag to apply the solution to the fittings. For the 
initial leak test, make sure the liquid propane 
cylinder is full. 
 
TO TEST 
1.  Make sure the control valves are in the “OFF” 
position, and turn the gas supply “ON”.  
 
2.  Apply the soap solution to all pipe fittings, from 
the liquid propane cylinder up to and including 
the connections to the burners. Soap bubbles 
will appear where a leak is present.  
 
3.  If a leak is present, immediately turn off the gas 
supply and tighten leaky fittings. 
 
4.  Turn the gas back “ON” and recheck.  
 
5.  Should the gas continue to leak from any of the 
fittings, turn off the gas supply and contact 
customer service at 1-800-554-5799. 
 
 
 
 
 
 
 
 
Only those parts recommended by the 
manufacturer should be used on the grill. 
Substitutions will void the warranty.  
 
GAS FLOW CHECK 
Each grill burner is tested and adjusted at the 
factory prior to shipment. However, variations in the 
local gas supply may make it necessary to adjust 
the burners.  
 
Flames should be blue and stable with no yellow 
tips, excessive noise or lifting.  
 
If any of these conditions exist, first check to see if 
the burner is blocked by dirt, debris, spider webs, 
etc.  If the burners are clear of foreign objects or 
debris, please contact customer service at 1-800-
554-5799 for further assistance. 
 
Always check for leaks after every liquid propane 
cylinder change. 
It is handy to keep a spray bottle of soapy water 
near the shut-off valve of the gas supply line. Spray 
all the fittings. Bubbles indicate leaks. 
 
Disconnected liquid propane cylinders must have 
threaded valve plugs tightly installed, and must not 
be stored in a building, garage or any other 
enclosed area. 
 
 
 
LEAK TESTING
 
 
 
WARNING 
Storage of an outdoor cooking gas appliance 
indoor is permissible only if the cylinder is 
disconnected and removed from the outdoor 
cooking gas appliance. 
6.  If it is evident there is excessive abrasion or 
wear, or the hose is cut, it must be replaced prior 
to the outdoor cooking gas appliance being put 
into operation.