Multiquip GB114BS/BP ユーザーズマニュアル
GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 25
MAINTENANCE
For a prolonged life cycle an extended quality follow the
recommended GloBug lighting system service guidelines
as referenced in Figure 30 and Table 4.
recommended GloBug lighting system service guidelines
as referenced in Figure 30 and Table 4.
Periodic Check and Maintenance
Table 4.
Figure
Part
Check Item
Solution
Frequency
Lamp
L1
Lamp (Base)
Lamp base loose?
Screw in securely
❖
L2
Connector
Cable disconnected or loose?
Connect securely
❖
L3
Lamp Holder
Lamp holder loose?
Replace
❖
L4
Pipe Frame
Frame pipe skewed?
Replace
❖
L5
Lamp
Defective lamp?
Replace
■
Balloon
B1
Balloon (Envelope)
Defective or dirty?
Replace
❖
B2
Zipper
Broken?
Replace
❖
B3
Fan Motor (Blower)
Not working properly?
Repair or replace
❖
B4
T-Handle bolt (Balloon) Broken?
Replace
❖
Electric
E1
Power Cable
Defective or worn cable?
Replace
❖
E2
Plug
Damaged?
Replace
❖
E3
Lamp Switch
Damaged or not working properly?
Replace
❖
Pole
P1
Clamp
Broken?
Repalce
❖
P2
Support pipe
Support pipe bent or damaged?
Replace
❖
P3
Support bolt
Support bolt loose?
Tighten securely
❖
P4
Straight pole
Straight pole bent or damaged?
Repalce
❖
P5
Offset pole
Offset pole bent or damaged?
Replace
❖
P6
Offselt bolt
Offset bolt loose?
Tighten securely
❖
❖ - Daily Check ■ - Every 20 Hours