Furuno 1763c ユーザーズマニュアル

ページ / 84
 
 
 2-1
2. WIRING 
2.1 Standard 
Wiring 
All wirings are terminated at the rear of the display unit. 
Signal cable connector
Connect signal cable
from antenna here.
DATA 1 (7P)
Connect 
GPS receiver 
GP-310B/320B or 
NMEA equipment 
here.
DATA 2 (6P)
Connect heading
sensor here.
(AD or NMEA format)
DATA 3 (7P)
Connect external 
buzzer (option), 
PC here. 
NETWORK (6P)
Connect other NavNet 
equipment (GD-1700, 
ETR-6/10N, ETR-30N, 
HUB etc. ) here. 
CAUTION
The power cable is shipped with 10 A fuse. 
Replace the fuse to 5 A (supplied as 
spare partrs) when the ship's mains is 
24 VDC. And then, attach 5 A label to 
the fuse cover on power cable. 
Use of wrong fuse can result in damage 
to the equipment.
CAUTION
Tighten the boot-band
securely to ensure
watertightness.
12-24 VDC
Connect power
cable here.
Ground terminal
Connect ground wire between
here and ship's ground.
Ground the
equipment to
prevent 
interference.
CAUTION
 
Display unit, rear view 
 