Hoshizaki 73180 ユーザーズマニュアル

ページ / 60
44
4. Removal and Replacement of Evaporator
NOTICE
• Always install a new drier every time the sealed refrigeration system is opened. Do 
not replace the drier until after all other repair or replacement has been made.
• When brazing, protect the drier by using a wet cloth to prevent the drier from 
overheating. Do not allow the drier to exceed 250°F (121°C).
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical 
outlet. 
2) Close the water supply line shut-off valve.
3) Remove all ice from the storage bin.
4) While maintaining a hold on the door, remove the hinge stop pin from hinge (B). Pull out 
the bottom of the door slightly, then gently remove the door from hinge (A). See Fig. 10.
5) Remove the top panel.
6) Remove the spout. 
7) Remove the rear panels. 
8) Remove the clamp securing the drain plug, then lower the drain hose into a container. 
Remove the drain plug to drain the water from the reservoir and evaporator assembly. 
See Fig. 12.
9) Disconnect the drain hose and reservoir hose from the evaporator.  
10) Remove the packing.
11) Remove the socket head cap screws securing the extruding head and evaporator flange. 
Remove the evaporator flange, then grasp the cutter and carefully lift out the cutter and 
extruding head. Grasp the top of the auger and carefully lift out the auger. When pulling 
out the auger, the upper part of the mechanical seal should come out with it.  
12) Remove the evaporator condensate drain pan.
13) Install a temporary tap-line valve on the high side, then recover the refrigerant and store 
it in an approved container.
14) Disconnect the inlet and outlet tubing.
15) Remove the socket head cap screws securing the evaporator to the lower housing.
16) Lift off the evaporator.
17) Inspect the mechanical seal and O-ring prior to installing the new evaporator. The 
mechanical seal consists of two parts. One moves along with the auger, and the other 
is fixed on the lower housing. If the contact surfaces of these two parts are worn, 
cracked or scratched, the mechanical seal may cause water leaks and should be 
replaced. Instructions for removing the mechanical seal and lower housing are located 
later in this procedure.
18) Make sure the lower mechanical seal and the O-ring are in place, then place the 
evaporator assembly in position. Secure the evaporator to the lower housing using the 
socket head cap screws.