Mitsubishi Electronics MR-J3-B-RJ080W ユーザーズマニュアル

ページ / 144
6. TROUBLESHOOTING 
6 -  7 
 
Display Name 
Definition 
Cause 
Action 
E0 Excessive 
regeneration 
warning 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
E1 Overload 
warning 1 
 
 
 
E2 
1. Ambient temperature of direct drive 
motor is over 40  (104 ). 
Check environment so that ambient 
temperature is 0 to 40   (32 to 104 ). 
 
Direct drive 
motor overheat 
warning 
Direct drive motor 
temperature rose and 
exceeded 85  of the 
alarm occurrence 
level. 
2. Direct drive motor is overloaded. 
1. Reduce load. 
2. Check operation pattern. 
3. Replace direct drive motor that provides 
larger output. 
 
 
 
3. Thermistor in direct drive motor is 
faulty. 
Replace the direct drive motor. 
E3 Absolute 
position counter 
warning 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
E4 Parameter 
warning 
 
 
 
E6 Servo 
forced 
stop warning 
 
 
 
E7 Controller 
forced stop 
warning 
 
 
 
E8 Cooling 
fan 
speed reduction 
warning 
 
 
 
E9 
Main circuit off 
warning 
 
 
 
EC Overload 
warning 2 
 
 
 
ED Output 
watt 
excess warning