(2) Structure 
The control circuit provide safe separation to the main circuit in the servo amplifier. 
Direct drive motor
M
Cabinet
Servo
amplifier
Reinforced insulating type
24VDC
power
supply
Molded-case 
circuit breaker
Magnetic
contactor
MC
MCCB
 
(3) Environment 
(a)  Operate the servo amplifier at pollution degree 2 or 1 set forth in EN 60664-1. For this purpose, install 
the servo amplifier in a cabinet which is protected against water, oil, carbon, dust, dirt, etc. (IP54). 
 
(b) Environment 
 
Item Environment 
[ ] 
(Note 2) 0 to 55 
Operation 
[ ] 
32 to 131 
[ ] 
20 to 65 
(Note 1) 
Ambient temperature 
Storage,  
Transportation 
[ ] 
4 to 149 
Ambient humidity 
Operation,  
Storage,  
Transportation 
90   RH or less 
Operation,  
Storage 
1000m or less 
Maximum altitude 
Transportation 
10000m or less 
Note 1. Ambient temperature is the internal temperature of the cabinet. 
          2. The servo amplifier 200V 3.5kW or less can be mounted closely. In this case, keep the 
ambient temperature within 0 to 45   (32 to 113 ) or use the servo amplifier with 75  
or less of the effective load ratio. 
 
(4) Power supply 
(a)  This servo amplifier can be supplied from star-connected supply with earthed neutral point of 
overvoltage category   set forth in EN 60664-1. However, when using the neutral point of 400V system 
for 1-phase supply, a reinforced insulating transformer is required in the power input section. 
 
(b)  For the interface power supply, use a 24VDC power supply with reinforced insulation on I/O terminals.