216
(3) Set frequency when stop-on-contact control (Pr. 270 = 1, 3, 11 or 13) is selected
⋅ The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are selected together.
Bold frame indicates stop-on-contact control is valid.
⋅ Stop-on-contact control is disabled when remote setting function is selected (Pr. 59 = 1 to 3).
CAUTION
⋅ Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may affect the other functions. Set
parameters after confirming the function of each terminal.
♦ Parameters referred to 
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27  (multi-speed setting)  
 Refer to page 165
Pr. 15 Jog frequency  
 Refer to page 167
Pr. 22 Stall prevention operation level, Pr. 48 Second stall prevention operation current 
 Refer to page 152
Pr. 22 Torque limit level 
 Refer to page 100
Pr. 59 Remote function selection 
 Refer to page 169 
Pr. 72 PWM frequency selection 
 Refer to page 284
Pr. 79 Operation mode selection 
 Refer to page 313
Pr. 95 Online auto tuning selection   
 Refer to page 199
Pr. 128 PID action selection 
 Refer to page 361
Pr. 178 to Pr. 189 (input terminal function selection) 
 Refer to page 231
Pr. 270 = 2, 3 (load torque high speed frequency control) 
 Refer to page 374
Pr. 292 Automatic acceleration/deceleration 
 Refer to page 163, 180
 
Input signal (  = on)
Set Frequency
RH RM
RL
RT
JOG
Pr. 4 Multi-speed setting (high speed)
Pr. 5 Multi-speed setting (middle speed)
Pr. 6 Multi-speed setting (low speed)
By 0 to 5V(0 to 10V), 4 to 20mA 
input
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 25 Multi-speed setting (speed 5)
Pr. 4 Multi-speed setting (high speed)
Pr. 15 Jog frequency
Pr. 24 Multi-speed setting (speed 4)
Pr. 5 Multi-speed setting (middle speed)
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 27 Multi-speed setting (speed 7)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
By 0 to 5V(0 to 10V), 4 to 20mA 
input
Input signal (  = on)
Set Frequency
RH RM
RL
RT
JOG