Mitsubishi Electronics FR-A700 ユーザーズマニュアル

ページ / 523
314
Selection of operation mode and operation location
(1) Operation mode basics
(2) Operation mode switching method
⋅ The operation mode is to specify the source of
inputting the start command and frequency
command of the inverter.
⋅ Basically, there are following operation modes.
External operation mode: For inputting start
command and frequency command by an external
potentiometer and switches which are connected
to the control circuit terminal.
PU operation mode: For inputting start command
and frequency command by operation panel (FR-
DU07), parameter unit (FR-PU04/FR-PU07) and
RS-485 communication with PU connector. 
Network operation mode (NET operation
mode):
 For inputting start command and
frequency command by RS-485 terminal and
communication options. 
⋅ The operation mode can be selected from the
operation panel or with the communication
instruction code.
REMARKS
⋅ Either "3" or "4" may be set to select the PU/external combined operation, and these settings differ in starting method.
⋅ In the initial setting, the stop function by 
of the PU (FR-DU07/FR-PU07) (PU stop selection) is valid also in other than the
PU operation mode. (Pr. 75 Reset selection/disconnected PU detection/PU stop selection. Refer to page 305.)
REMARKS
⋅ For switching of operation by external terminals, refer to the following:
PU operation external interlock signal (X12 signal)  
 page 318
PU-external operation switch-over signal (X16)  
 page 319
PU-NET operation switchover signal (X65), External-NET operation switchover signal (X66)  
 page 320
Pr. 340 Communication startup mode selection   
 page 321
Network operation mode
Network operation 
mode
External 
operation 
mode
PU operation 
mode
Personal 
computer
Personal 
computer
Operation 
panel
Programmable controller
Potentiometer Switch
RS-485 
terminals
Inverter
Communication 
option
External terminal
Personal 
computer
USB
connector
PU connector
Switching through the network
Switch to the Network operation 
mode through the network.
Switch to External 
operation mode through 
the network.
External operation
Switching with the PU
Press         on
the PU to light
Network operation
PU operation
Network operation
PU operation
When "0, 1, or 2" is set in 
Pr. 340
When "10 or 12" is set in 
Pr. 340
Press        on the PU to light
Press         on 
the PU to light
Press        on the PU to light