(1)
PM sensorless vector control setting by selecting IPM in the parameter setting
mode on the operation panel
 
(
)
POINT
· The parameters required to drive an MM-CF IPM motor are automatically changed as a batch.  (Refer to
Operation 
example
Initialize the parameter setting for an MM-CF IPM motor by selecting IPM in the parameter setting mode on the 
operation panel.
Setting
Description
0
Parameter settings for a general-purpose motor
3003
Parameter settings for an IPM motor MM-CF (rotations per minute)
REMARKS
· Performing IPM parameter initialization by selecting IPM in the parameter setting mode on the operation panel
automatically changes the Pr. 998 IPM parameter initialization setting.
· In the initial parameter setting, the capacity same as the inverter capacity is set in Pr. 80 Motor capacity. (Refer to page
16.) To use a motor capacity that is one rank lower than the inverter capacity, set Pr. 80 Motor capacity before
performing IPM parameter initialization by selecting the mode on the operation panel.
· To set a speed or to display monitored items in frequency, set Pr. 998. (Refer to page 4.)
Display
Operation
Flicker ... Parameter setting complete!!
 Turn           to read another parameter.
 Press         twice to show the automatic parameter setting (AUTO).
 Press         to show the setting again.
The parameter 
number read 
previously appears.
P.RUN indicator is lit.
1. 
Screen at power-ON
 
The monitor display appears.
2. 
Parameter setting mode
 
Press        to choose the parameter setting 
mode.
3. 
Selecting the parameter
 
Turn         until            (IPM parameter 
initialization) appears.
4. 
Displaying the setting
 
Press        to read the currently set value. 
"    " (initial value) appears.
5. 
Selecting the setting
 
Turn        to change it to the set value
      "            ".
6. 
Parameter setting
 
Press        to set.