Manual controller
FR-AX (Note 4)
For independent operation. With frequency meter, frequency 
setting potentiometer and start switch.
Common to 
all models
DC tach. follower
FR-AL (Note 4)
For joint operation using external signals. (0 to 5VDC, 0 to 
10VDC) (1.5VA) (Note 2)
Three speed selector
FR-AT (Note 4)
For three-speed (high, middle, low) switching operation. (1.5VA)
Motorized speed setter
FR-FK (Note 4)
For remote operation. Allows operation to be controlled from 
several places. (5VA)
Ratio setter
FR-FH (Note 4)
For ratio control. Allows ratios to be set to five inverters. (3VA)
PG follower (Note 4)
FR-FP
For follow-up operation using the signal of a pilot generator (PG). 
(3VA)
Master controller 
(Note 4)
FR-FG
For parallel operation of several (up to 35) inverters. (5VA)
Soft starter (Note 4)
FR-FC
For soft start and stop. Allows parallel operation and acceleration/
deceleration. (3VA)
Deviation detector 
(Note 4)
FR-FD
For synchronous operation. Used with a deviation sensor and 
synchro. (5VA)
Preamplifier (Note 4)
FR-FA
Can be used as A/V conversion or operational amplifier. (3VA)
Pilot generator (Note 4)
QVAH-10
For follow-up operation. 70/35VAC 500Hz (at 2500r/min)
Deviation sensor 
(Note 4)
YVGC-500W-NS
For synchronous operation (mechanical deviation detection). 
Output 90VAC/90
°
Frequency setting 
potentiometer (Note 4)
WA2W 1k
Ω
For frequency setting. Wire-wound type. 2W1K
Ω
 B characteristic.
Frequency meter 
(Note 4)
YM206NRI 1mA
Dedicated frequency meter (up to 120Hz scale). Moving-coil DC 
ammeter.
Calibration resistor 
(Note 4)
RV24YN 10k
Ω
For calibration of the frequency meter. Carbon-film type. B 
characteristic.
Inverter setup software
FR-SW
-SETUP-WE
Supports steps from inverter start-up to maintenance. (FR-SW
-
SETUP-WJ is Japanese version.)
Note: 1. "H" in the type code indicates 400V class. Power supply specifications of FR series controllers
and setters: 200VAC 50Hz, 200V/220VAC 60Hz, 115VAC 60Hz.
2. Rated power consumption
3. The intercompatibility attachment (FR-A5AT
……
) is required to mount the inverter, with the
exception of some models.
4. Options available in Japan only.
5. "AT" in the type code indicates an enclosure inside installation structure model and without "AT"
indicates a heatsink outside mounting structure model. For the 37K or more, it can be used in
either way by changing its mounting foot position and does not have "AT" in the type code.
Name
Type
Application, Specifications, etc.
Applicable 
Inverter