Mitsubishi Electronics FR-A500 ユーザーズマニュアル

ページ / 257
242
Com
m
unic
a
ti
on
funct
ions
117
Station number
11
91
1
118
Communication speed
12
92
1
119
Stop bit length/data length
13
93
1
120
Parity check presence/absence
14
94
1
121
Number of communication retries
15
95
1
122
Communication check time interval
16
96
1
123
Waiting time setting
17
97
1
124
CR, LF presence/absence selection
18
98
1
P
ID cont
rol
128
PID action selection
1C
9C
1
129
PID proportional band
1D
9D
1
130
PID integral time
1E
9E
1
131
Upper limit
1F
9F
1
132
Lower limit
20
A0
1
133
PID action set point for PU operation
21
A1
1
134
PID differential time
22
A2
1
Co
mm
ercial powe
r
supply-inv
e
rt
er
sw
it
c
h
-over
135
Commercial power supply-inverter switch-over 
sequence output terminal selection
23
A3
1
136
MC switch-over interlock time
24
A4
1
137
Start waiting time
25
A5
1
138
Commercial power supply-inverter switch-over 
selection at alarm occurrence
26
A6
1
139
Automatic inverter-commercial power supply 
switch-over frequency
27
A7
1
B
a
ckl
as
h
140
Backlash acceleration stopping frequency
28
A8
1
141
Backlash acceleration stopping time
29
A9
1
142
Backlash deceleration stopping frequency
2A
AA
1
143
Backlash deceleration stopping time
2B
AB
1
Display
144
Speed setting switchover
2C
AC
1
145
PU display language selection
Additional
functions
148
Stall prevention operation level at 0V input
30
B0
1
149
Stall prevention operation level at 10V input
31
B1
1
Curr
ent
det
ect
ion
150
Output current detection level
32
B2
1
151
Output current detection period
33
B3
1
152
Zero current detection time
34
B4
1
153
Zero current detection period
35
B5
1
S
ub f
unct
ion
s
154
Voltage reduction selection during stall prevention 
operation
36
B6
1
155
RT signal activated condition
37
B7
1
156
Stall prevention operation selection
38
B8
1
157
OL signal waiting time
39
B9
1
158
AM terminal function selection
3A
BA
1
Additional
function
160
User group read selection
00
80
2
Re
s
ta
rt a
fte
r
inst
ant
aneo
us
power f
a
ilure
162
Automatic restart after instantaneous power 
failure selection
02
82
2
163
First cushion time for restart
03
83
2
164
First cushion voltage for restart
04
84
2
165
Restart stall prevention operation level
05
85
2
Initial 
monitor
170
Watt-hour meter clear
0A
8A
2
171
Actual operation hour meter clear
0B
8B
2
Us
er
func
ti
ons
173
User group 1 registration
0D
8D
2
174
User group 1 deletion
0E
8E
2
175
User group 2 registration
0F
8F
2
176
User group 2 deletion
10
90
2
Function
Parameter 
Number
Name
Data Codes
Read
Write
Link Parameter Extension Setting 
(Instruction code 7F/FF)