Furuno FAR-2167DS-BB ユーザーズマニュアル

ページ / 111
5-1
5. IO DATA
Available input and output data are shown in the tables below and input and output sentences are 
shown on the next page.
Note: This radar accepts position data fixed by WGS-84 geodetic datum only. Set the datum to 
WGS-84 on the EPFS (GPS, etc.) connected to this radar. If other type of datum is input, the error 
message "DATUM" appears and the AIS feature is inoperative.
Input
Output
 
Data
Specifications
Contents
Remarks
Heading 
signal
Synchro or step
GC-10 required
Switching between AD-10 
and IEC 61162 is done 
from menu.
AD-10 format
External AD-100
IEC 61162-2
Speed signal
IEC 61162-1
Navigator 
data
IEC 61162-1
Position, course, speed, LORAN-
C TD, waypoint, route, time, wind 
speed and direction, current data, 
depth, water temperature, roll, 
pitch, ROT
External 
radar signal
Heading, Bearing, 
Trigger, Video
No GAIN, STC control
Operate as remote display
Alarm ACK 
input
Contact closure 
signal
Input signal from alarm 
system
Track Control 
unit
RS-422
Option
Data
Specifications
Contents
Remarks
Radar system 
data
RS-232C
RSD, OSD, TLL
For PC plotter
ARPA data
IEC 61162-1
TTM
For ECDIS
Remote display 
signal
Heading, Bearing, Tx 
Trigger, Video
2 ports
External LCD 
monitor signal
DVI
Same as main monitor unit
2 systems max.
External CRT 
monitor signal
R, G, B, H, V
Same as main monitor unit
Option
Alarm signal
Contact closure
signal
Output to alarm system by using 
photo-relay
4 outputs, output
content selected from 
menu.