Troubleshooting Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
12 
16023522 
©2004 Maytag Services
 
 
Problem Possible 
Cause 
Correction 
No gas flows to burner. 
Ignitor glows red. 
Failed ignitor. .................................................
 
 
Gas pressure too high ...................................
 
 
 
Failed gas valve.............................................
Loose wire connection or broken wire ...........
•  Check ignitor current draw, 3.2 – 
3.6 Amps. Replace ignitor, if it 
fails test. 
•  Check for correct gas pressure. 
Natural gas pressure should be 4" 
WCP and LP gas pressure should 
be 10" WCP. 
•  Check gas valve for continuity. 
•  Verify all connections are clean 
and tight, replace broken wire. 
Gas flows to bake/broil 
burner, but burner does not 
light. 
Ignitor positioned too far from burner ............
 
Dirt or grease in orifice or burner...................
Insufficient gas pressure ...............................
 
 
 
Power outage ................................................
•  Reposition ignitor closer to 
bake/broil burner. 
•  Clean orifice or burner. 
•  Check for correct gas pressure. 
Natural gas pressure should be 5" 
WCP and LP gas pressure should 
be 10" WCP. 
•  Verify power is present at unit. 
Verify that the circuit breaker is 
not tripped. 
•  Replace household fuse, but do 
not fuse capacity. 
Broil burner shuts off shortly 
after the start of self-clean 
operation. Bake and broil 
functions operate normally. 
Power outage ................................................
 
 
 
 
Control Error ..................................................
•  Verify power is present at unit. 
Verify that the circuit breaker is 
not tripped. 
•  Replace household fuse, but do 
not fuse capacity. 
•  See “Control Systems 
Troubleshooting.” 
Fan motor does not operate. 
No power to fan motor ...................................
 
 
 
 
 
 
Failed fan motor or winding/frozen shaft .......
•  Check for 120 VAC supplied at 
fan motor. If no voltage is 
present, check for broken or 
loose wiring between fan motor 
and relay board. If voltage is 
present at fan motor, go to the 
next step. 
•  Check motor winding for 
continuity. Check for a frozen 
motor shaft. Check for broken 
wiring between motor and neutral 
terminal block.