Vinotemp VINO2500-4500SSR ユーザーズマニュアル

ページ / 25
                                                                                
- 16 -
If the function is enabled, the compressor is not energized for three minutes after 
controller power up. 
The function is also active in hot-gas defrost mode. 
 
5) LED & Display Messages 
 
1. LED 
off 
2. LED 
on 
3.  LED blinking 0.5s on/0.5s off 
4.  LED blinking 0.5s on/1.5s off 
5. Display 
A1 
6. Display 
A2 
1.  Compressor and defrost deactivated 
2. Compressor 
energized 
3. Defrost 
activated 
4. Sensor 
fault 
5.  Regulation probe fault 
6.  Defrost probe fault 
 
3.  Use of the Digital Controller  
 
Fig. 3.3 Digital Controller 
 
1) Display 
During normal operating conditions, the display shows the value measured by 
the air regulation probe. In case of active alarm, the temperature flashes 
alternately to the code alarm.  
 
1.1 LED Functions 
 
 
1.2 Front Panel Commands