Models BBRN/BBSN Installation & Operation Manual
Printed in USA 
12 
0213
TroubleshooTInG
Before Calling For Service
If the unit appears to be malfunctioning, read through the Operation section in this manual first. If the 
problem persists, check through this troubleshooting section. Locate the problem and refer to the cause 
and remedy before calling for service. The problem could be something that can be solved without a 
service call.
DANGER
Never attempt to repair or perform maintenance on the unit until the main electrical 
power to the unit has been disconnected!
Problem
Cause
Solution
No interior light.
Rocker switch in Off position.
Turn switch on.
LED board inoperable.
Contact your selling dealer.
Light stays on when door is 
closed.
Manual switch on.
Turn manual switch off.
Noisy operation.
Soft sounds from compressor, fan 
motor and valves heard.
Normal operation.
LED Controller display is flashing 
.“P1”.
Thermostat probe failure. 
Contact your selling dealer.
LED Controller display is flashing 
“HA”.
Internal compartment has exceeded the 
high temperature alarm preset value for 
over 30 minutes.
Make sure door is completely closed.
Check door gasket seal. Replace if 
necessary. 
Check condenser and clean if necessary.
Make sure louvered plate is unobstructed.
If surrounding ambient temperature has 
changed dramatically recently, compartment 
temperature may be affected.
Make sure interior light is off.
Warm product placed in cabinet recently. Wait 
24 hours for product to chill then recheck 
temperature.
LED Controller display is flashing 
“LA”.
Internal compartment has exceeded the 
low temperature alarm preset value for 
over 30 minutes.
Make sure door is completely closed.
Check door gasket seal. Replace if 
necessary.
If surrounding ambient temperature has 
changed dramatically recently, compartment 
temperature may be affected.
LED Controller display is flashing 
“EE”.
Controller has a data or memory failure. Reset both compartment presets.
If problem persists, contact your Perlick 
Service Department.
Unit is not running.
No power to the unit. 
Condenser dirty.
Home circuit breaker tripped. Reset circuit 
breaker.
ON/OFF keypad is off. Turn on.
Clean the condenser.
Compartments are warmer than 
usual.
Control preset not set properly.
Light staying on.
Condenser dirty or obstructed.
Door is open or has been opened more 
frequently lately.
Internal louvers and/or fan guard 
obstructed.
Warm product placed in cabinet 
recently.
Reset compartments presets.
Turn manual light switch off.
Clean condenser and clear obstruction.
Wait 24 hours and recheck temperature. 
Reset preset temperature if necessary.
Make sure louvers and/or fan is not 
obstructed.