Electrolux R134A プリント

ページ / 2
service data sheet
241958200
reFriGeratOr draWers - r134a 
impOrtant saFety nOte
The information provided herein is designed to assist qualified 
repair personnel only. Untrained persons should not attempt to 
make repairs due to the possibility of electrical shock. Disconnect 
power cord before servicing this appliance.
impOrtant
If  any  green  grounding  wires  are  removed  during  servicing, 
they  must  be  returned  to  their  original  position  and  properly 
secured.
 
cautiOn
all electrical parts and wiring must be shielded from torch 
flame. dO nOt allow torch to touch insulation; it will char 
at 200°F and flash ignite (burn) at 500°F. excessive heat will 
distort the plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS 
AT MID-POINT CONTROL SETTING
type a with run/start           
capacitor
65°F (18°c) ambient
90°F (32°c) ambient
Operating Time
N/A
30 to 50%
Temperature
34º F to 45º F
34º F to 45º F
Low Side Pressure  (cut-in)
30 to 45 psig
208 to 310 kPa
30 to 45 psig
208 to 310 kPa
Low Side Pressure (cut-out)
-2 to 4 psig
-14 to 28 kPa
-2 to 4 psig
-14 to 28 kPa
High Side Pressure               
(last 1/3 cycle)
90 to 120 psig
621 to 827 kPa
130 to 175 psig
896 to 1207 kPa
Wattage (last 1/3 cycle)
85 to 125
85 to 125
Amps (running)
.75 to 1.2
.75 to 1.2
Base Voltage
115 vac (127 vac max)
cOndenser Fan mOtOr
Watts
rpm
amps
3.1
1100 CW Opposite Shaft
0.03 Running
evapOratOr Fan mOtOr
1.7 each
9000
.02 each
Width 
Height
Depth
23
13
/
16
 inch
34-35 inches
26
3
/
4
 inch
unit dimensions
nOte
Your Electrolux refrigerator drawers has been designed for 
built-in installation.  Your refrigerator drawers do not require 
additional air space for top, sides or rear.  The front grille must 
nOt be obstructed.
To ease unit installation and removal, it is recommended that 
the cabinet rough opening dimensions be increased by at least 
¼ inch over the dimensions given for your unit.
impOrtant: pLease return this sheet tO 
it’s OriGinaL LOcatiOn.
      
 WarninG
double drawer refrigerator drawers are designed to be 
built-in only. they can not be used for free-standing.
all screws supplied with the anti-tip Kit are for mounting 
the bracket directly to wall studs. these screws will not 
work if used with sheetrock (dry wall) or anything other 
than wall studs.