Top Mount Refrigerator - 18 Cu. Ft.
Professional
Top Mount Refrigerator Specifications 
 Product Shipping Weight (approx.) – 205 Lbs.
 An electrical supply with grounded three-prong receptacle is 
required. The power supply circuit must be installed in accordance 
with current edition of National Electrical Code (NFPA 70) and  
local codes & ordinances.
 Voltage Rating – 120V / 60 Hz / 15 Amps
 Connected Load (kW Rating) @ 120 Volts = .54 kW
 Amps @ 120 Volts = 4.5 Amps
 Always consult local and national electric & plumbing codes.
 Floor should be level surface of hard material, capable of supporting 
fully loaded refrigerator.
 Minimum 3/8" clearance required for sides and top of refrigerator 
with 1" clearance at rear to allow for ease of installation, proper air 
circulation, and plumbing / electrical connections.
 When installing refrigerator adjacent to wall, cabinet or other  
appliance that extends beyond front edge of unit, 20" minimum 
clearance recommended to allow for optimum 140° door swing, 
providing complete crisper access and removal. (Absolute 3"  
minimum clearance will ONLY allow for 90° door swing which  
will provide limited crisper access with restricted removal.)
 To ensure optimum performance, do not install in areas where 
temperature drops below 55° F or rises above 110° F and  
avoid installing in direct sunlight or close proximity to range, 
dishwasher or other heat source. 
 For proper ventilation, front grille MUST remain unobstructed.
 Recess electrical outlet when possible.
 Water recess on rear wall recommended to prevent water line damage.
 Water Pressure – Cold water line must provide between 30 and 100 
pounds per square inch (psi).
 Copper tubing with 1/4" O.D. recommended for water supply line  
with length equal to distance from rear of unit to household water 
supply line plus 7 additional feet. Optional Water Supply Installation 
Kits available.