U-Line 1175WC ユーザーズマニュアル

ページ / 28
14
1115WC, 1175WC
To defrost:
1. Turn unit off.
2. Remove all products from the interior and prop the 
door in an open position (2 in. (5 cm) minimum).
3. Allow the frost to completely melt naturally. Clean the 
interior and all removed components using a mild non-
abrasive detergent and warm water solution applied 
with a soft sponge or non-abrasive cloth. NOTE: DO 
NOT use any solvent-based or abrasive cleaners. They 
will discolor or damage the interior.
4. Dampen a soft sponge or non-abrasive cloth in clean 
water and wipe down the cabinet interior and removed 
components to remove any detergent residue. Rinse the 
sponge or cloth in clean water and repeat as necessary 
until the cabinet and components are clean. 
5. When the interior is dry, turn unit back on.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille 
free of dust and lint, and clean the condenser every three 
months. Depending on environmental conditions, more 
or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before 
cleaning the condenser.
WARNING
DO NOT touch the condenser fins. The condenser 
fins are SHARP and can be easily damaged.
IMPORTANT
IMPORTANT
DO NOT use any type of cleaner on the condenser 
unit.
Model 1115WC
1. Disconnect power to the unit.
Figure 10
2. Loosen the two screws (Figure 10, 1) completely.
NOTE: Screws are held in the grille by o-ring retainers, 
and will not come free of the grille.
3. Remove grille (Figure 10, 2) and grille cap (Figure 
10, 3) from unit.
Figure 11
4. Clean the condenser coil (Figure 11, 1) using a soft 
brush with a “combing” action or vacuum cleaner. Do 
not touch the condenser coil.
Figure 12
5. Make sure grille cap (Figure 12, 1) is behind grille in 
slots (Figure 12, 2) provided in grille before attaching 
grille to unit, and secure, but do not overtighten both 
grille screws (Figure 12, 3).
6. Reconnect power to the unit.
Model 1175WC
1. Disconnect power to unit.
Figure 13
2. Loosen the two screws (Figure 13, 1) completely.
NOTE: Screws are held in the grille by o-ring retainers, 
and will not come free of the grille.
3. Remove grille from unit.
2
3
1
ULIN_0155_A
ULIN_0156_A
1
ULIN_0157_A
2
3
1
2
1
ULIN_0158_A
ULIN_016357_30088.fm  Page 14  Tuesday, March 14, 2006  2:17 PM