U-Line 1175WC ユーザーズマニュアル

ページ / 28
22
1115WC, 1175WC
Troubleshooting Guide
DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on 
the unit until the main electrical power has been 
disconnected.
Troubleshooting - What to check when problems occur:
PROBLEM
POSSIBLE CAUSE
REMEDY
Unit does not operate and 
electronic display is blank.
No electrical supply
Plug unit in or check circuit breaker.
No interior light
Loose or burned out bulb
Tighten or replace bulb (See MAINTENANCE; LIGHT 
BULB REPLACEMENT).
Unit not cold enough. Check 
temperatures (see OPERATION for 
approximate temperatures).
Control set too warm
Set control to a cooler setting (See OPERATION). Allow 
24 hours for temperature to stabilize.
High ambient temperature or 
exposure to direct sunlight
Reposition unit.
Airflow to front grille blocked
Airflow must not be obstructed to front grille (See 
OPERATION).
Dirty condenser coils
Clean condenser (See MAINTENANCE; CONDENSER 
CLEANING).
Light staying on
Adjust door (See MAINTENANCE; DOOR ALIGNMENT 
CHECK AND ADJUSTMENT).
Door gasket not sealing properly
Adjust door (See MAINTENANCE; DOOR ALIGNMENT 
CHECK AND ADJUSTMENT).
Unit is too cold. Check temperatures 
(see OPERATION for approximate 
temperatures).
Control set too cold
Set control to a warmer setting (See OPERATION). Allow 
24 hours for temperature to stabilize.
Electronic display is blank and 
interior light is OFF with door OPEN.
Unit is in blackout/Sabbath mode 
(not Star K certified).
Exit blackout/Sabbath mode (not Star K certified) 
(See OPERATION).
Electronic display is blank and 
interior light is ON with door OPEN.
A display function has changed.
Touch and hold the WARMER button and touch and 
release the ON/OFF button three times, then release the 
temperature button. The display should become visible.
Electronic display shows repeating, 
randomly flashing symbols and 
partial characters.
A factory control mode has been 
inadvertently entered.
Touch and hold the warmer temperature button and 
touch and release the LIGHT button three times, then 
release the temperature button to exit the factory 
control mode. The set-point temperature should now 
be displayed.
Electronic display shows:
0, 1 to 16, or 99
A factory control mode has been 
inadvertently entered.
Repeatedly touch the WARMER button to advance any 
number shown to 99 and touch and release the LIGHT 
button. The set-point temperature should now be 
displayed.
Electronic display shows one or 
more of the following:
E1, E2, E4, E5, E6, E7, E8, E9, E10, P1.
The unit is displaying an error code.
Record the error code(s) displayed and call for service.
ULIN_016357_30088.fm  Page 22  Tuesday, March 14, 2006  2:17 PM