U-Line 1175WC ユーザーズマニュアル

ページ / 28
8
1115WC, 1175WC
Electronic Control Panel
Figure 5
Your Wine Captain has been designed to provide three 
temperature zones within the cabinet so the specific 
storage requirements of your finest wines can be satisfied.
The electronic control with digital display (Figure 5) is 
configured to show a single temperature continuously. 
This set-point temperature is a base number used by the 
controller to maintain the temperature zones in your unit. 
The factory default set-point is 50°F. This set-point 
temperature is used as a gauge if further temperature 
adjustments are required.
A DISPLAY OFF mode is available through the control 
panel. This mode allows you to control whether the 
display (Figure 5, 3) will be on or off whenever the door 
is closed. The button sequence that follows will switch 
between both modes:
1. Press and hold the WARMER button (Figure 5, 4), and 
within five seconds press the ON/OFF button (Figure 
5, 2)
 three times.
2. The display will be either visible or dark when the door 
is closed.
3. To return to the previous mode, repeat Step 1. 
Temperature Display Selection
U-Line products supplied for 110 VAC operation have 
temperatures displayed in a default Fahrenheit (°F) 
configuration (Figure 5, 3). Models supplied for 220 VAC 
operation have temperatures displayed in a default 
Celsius (°C) configuration.
The display can easily be adjusted for either type of 
temperature display. Press and hold the LIGHT button 
(Figure 5, 1) and within five seconds press the COOLER 
button (Figure 5, 5) three times to change the display as 
desired.
Temperature Display
To display all zone temperatures:
1. Press and hold the WARMER button (Figure 5, 4) for 
approximately five seconds and release when the °F 
symbol in the display (Figure 5, 3) begins to flash.
2. The display (Figure 5, 3) will scroll through three 
individual readings at two second intervals per 
temperature.
3. The °F symbol in the display will indicate the individual 
zone temperature being displayed as they are the 
scrolling.
• The top horizontal bar in the symbol indicates the 
upper cabinet zone.
• The middle horizontal bar in the symbol indicates 
the middle cabinet zone.
• The bottom horizontal bar in the symbol indicates 
the lower cabinet zone. 
4. After the third scroll cycle is completed, the display will 
return to the set-point temperature. 
Checking Product Temperature
Figure 6
To check the actual product temperature in your unit, 
insert an accurate thermometer into a plastic (non-
breakable) bottle that is partially filled with water. 
Tighten the bottle cap securely (Figure 6).
Place the bottle in the desired area for 24 hours. Refrain 
from opening the unit during the testing period. After 24 
hours, check the temperature of the water. If required, 
adjust the temperature control in a small increment (See 
ADJUSTING TEMPERATURE). 
5
4
3
2
1
ULIN_0181_A
ULIN_0093_A
ULIN_016357_30088.fm  Page 8  Tuesday, March 14, 2006  2:17 PM