of the system.  The AquaForce
®
 30XW 
chiller's positive pressure design 
ensures that air, moisture and other 
performance degrading contaminants 
are not sucked inside the chiller. Purge 
units and their associated maintenance 
are no longer necessary.
Refrigerant isolation valves
The refrigerant isolation valves enable 
service personnel to store the refriger-
ant charge in the evaporator or con-
denser during servicing.  These valves 
also allow the refrigerant to be stored 
inside the chiller during shipment from 
the factory minimizing start-up time. 
During servicing, the in-chiller storage 
reduces refrigerant loss and eliminates 
time-consuming transfer procedures. 
As a self-contained unit, the AquaForce 
30XW chiller does not require addi-
tional remote storage systems.
Optional suction service valves
The optional suction service valves 
allow for further isolation of the com-
pressor from the evaporator vessel.
Marine container shipment
The compact design allows for con-
tainer shipment to export destinations, 
ensuring quality while reducing ship-
ping cost.
Heat exchangers
The Aquaforce 30XW chillers utilize 
mechanically cleanable shell and tube 
evaporators and condensers available 
with a complete line of waterbox 
options to meet project specific 
requirements. One, two, and three 
pass arrangements are available to 
meet a wide variety of flow conditions. 
Nozzle in head and marine waterboxes 
are available to meet 150 psig        
(1034 kPa) and 300 psig (2068 kPa) 
piping requirements.
Heat exchanger features include:
ASME certified construction
An independent agency certifies the 
design, manufacture, and testing of all 
heat exchangers to American Society 
of Mechanical Engineers (ASME) stan-
dards, ensuring heat exchanger safety, 
reliability and long life. The ASME     
U-stamp is applied to the refrigerant 
side of the evaporator and condenser 
and is applied to the water side of these 
heat exchangers when 300 psig   
(2068 kPa) marine waterboxes are  
provided.
Electronic thermal-dispersion flow 
switch
An electronic thermal-dispersion flow 
switch switch is included with the evap-
orator. The switch is factory installed 
and tested and contains no moving 
parts for high reliability.
High performance tubing
Carrier's AquaForce chillers utilize 
advances in heat transfer technology 
providing compact, high-efficiency 
heat exchangers. Tubing with 
advanced internally and externally 
enhanced geometry improves chiller 
performance by reducing overall resis-
tance to heat transfer while reducing 
fouling.
Evaporator tube expansion
Evaporator tube expansion at center 
support sheets prevents unwanted tube 
movement and vibration, thereby 
reducing the possibility of premature 
tube failure. Tube wall thickness is 
greater at the expansion location, sup-
port sheets, and end tube sheets, to 
provide maximum strength and long 
tube life.
Closely spaced intermediate sup-
port sheets
Support sheets prevent tube sagging 
and vibration, thereby increasing heat 
exchanger life.
Refrigerant filter isolation valves
These valves allow filter replacement 
without pumping down the chiller, 
reducing service time and expense.
Microprocessor controls
The AquaForce 30XW screw chiller 
controls communicate in easy to under-
stand English, making it as easy as pos-
sible to monitor and control each 
chiller while maintaining fluid tempera-
tures. Controls are available with 
French, Portuguese and Spanish as 
standard configuration options. These 
controls result in higher chiller reliabil-
ity, simplified training and correspond-
ingly lower operational and 
maintenance costs.
Two user interface options are avail-
able, the Touch Pilot™  display and the 
Navigator™ module.
The Touch Pilot  display is an easy to 
use touch screen display that provides 
simple navigation for configuration and 
control of the 30XW units.
Carrier's exclusive handheld Naviga-
tor display provides convenience and 
powerful information in the palm of 
your hand. The Navigator display helps 
technicians to quickly diagnose prob-
lems and even prevent them from 
occurring.
All 30XW units are ready to be used 
with Carrier Comfort Network
®
 (CCN) 
devices.
Controls features include:
Automatic capacity override
This function unloads the compressor 
whenever key safety limits are 
approached, increasing unit life.
Chilled liquid reset
Reset can be accomplished manually or 
automatically from the building man-
agement system. For a given capacity, 
reset allows operation at slower com-
pressor speeds, saving energy when 
warmer chilled liquid can be used. 
Demand limiting
This feature limits the power draw of 
the chiller during peak loading condi-
tions. When incorporated into the 
CCN building automation system, a red 
line command holds chillers at their 
present capacity and prevents any 
other chillers from starting. If a load 
shed signal is received, the compres-
sors are unloaded to avoid demand 
charges whenever possible.
Ramp loading
Ramp loading ensures smooth pull-
down of liquid loop temperature and 
prevents a rapid increase in compres-
sor power consumption during the 
pulldown period.
Automated controls test
The test can be executed prior to start-
up to verify that the entire control sys-
tem is functioning properly.
365-day real time clock
This feature allows the operator to pro-
gram a yearly schedule for each week, 
weekends, and holidays.
Occupancy schedules
Schedules can be programmed into the 
controller to ensure that the chiller 
operates when cooling is required and 
remains off when not needed by the 
tenants or process.