When used as an extractor unit, the hood must be fitted with a
100mm diameter hose.
100mm diameter hose.
If the fumes must be forced out through the wall, you must obtain
a MKZ sizable wall exhaust pipe (with external exhaust and air
intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our
optional parts.
a MKZ sizable wall exhaust pipe (with external exhaust and air
intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our
optional parts.
When installing the hood, make sure you respect the follow-
ing minimum distance from the top edge of the cooking hob/
ring surfaces:
ing minimum distance from the top edge of the cooking hob/
ring surfaces:
electric cookers
650 mm
gas cookers
700 mm
coal and oil cookers
900 mm min.
Where flexible ducting is fitted the length should be no more
than:
— 3 metres with one 90° bend
— 2 metres with two 90° bends.
Bends of more than 90° will reduce the efficiency of the hood
and reduce the air flow.
than:
— 3 metres with one 90° bend
— 2 metres with two 90° bends.
Bends of more than 90° will reduce the efficiency of the hood
and reduce the air flow.
General details
The hood is supplied as a ducted version, but may also be used
in recirculation mode by inserting a charcoal filter (Special
accessories).
in recirculation mode by inserting a charcoal filter (Special
accessories).
The air is ducted out through a pipe which is connected to the
outlet hole A (fig. 1) by means of a coupling flange B.
outlet hole A (fig. 1) by means of a coupling flange B.
To connect the hood to a wall box, you use hoses and wall boxes
as offered on the AEG price list as optional extras.
as offered on the AEG price list as optional extras.
Extractor
version
version
1
A
B