SUPPLY
Fig. 5 - Wiring Diagram
CAUTION
BE SURE ALL WIRING COMPLIES WITH
LOCAL AND NATIONAL ELECTRICAL CODES AND
HOUSING IS PROPERLY GROUNDED.
TO INSTALL IN EXISTING HOMES
1. Determine  location  of  ventilator.  Check  wall  for  studs
and obstructions.
2. Working  inside  wall  first,  draw  a  circle  9
1
8
”  in  diameter
at  determined  location.  Be  sure  opening  is  at  least  one
inch from studs. (See Figure 2.)
3. Carefully  saw  opening  in  plaster.  Remove  just  enough
insulation  to  allow  sleeve  to  pass  through,  exposing
sheathing.  Mark  center  of  the  hole  on  the  sheathing.  At
this point, drill small hole to outside.
4. Now  work  from  the  outside.  Using  hole  as  a  center
point,  draw  a  circle  on  outside  wall  9
1
8
”  in  diameter.
Saw  opening.  In  case  of  brick  or  stone,  use  hammer
and chisel to make opening. (See Figure 6.)
5. Install  door  and  outside  sleeve  assembly  from  outside.
Caulk  and  level  before  nailing  tight.  Remove  tape,  per-
mitting damper door to open. (See Figure 3.)
6. Working  from  inside  the  house,  slide  inside  sleeve  into
place temporarily. Determine whether to remove one or 
both knockouts from outside sleeve, permitting outlet box 
to drop through. Remove knockouts from outside sleeve. 
(See Figure 4.)
7. Slide  inside  sleeve  into  place  again  and  pull  power
cable  through  outlet  box  opening.  This  will  determine
length of power cable to ventilator. Power line should be 
run to switch box holding toggle switch. For more efficient 
operation, an optional timer is available. Attach cable to 
outlet box, using approved connector, and splice cable to 
receptacle leads in outlet box cover. Ground wire may be 
attached to grounding bolt in outlet box. (See Wiring 
Diagram, Figure 5.)
8. Adjust  inside  sleeve  so  that  flange  is  flush  with  finished
wall.  Using  metal  screws,  fasten  inside  housing  to 
outside housing. Screws are supplied with ventilator.
9. Perform  Steps  6-8  as  for  new  homes  to  finish 
installation.
TYPICAL INSTALLATIONS
Fig. 6
STANDARD WALL SWITCH