Sharp MMD24B ユーザーズマニュアル

ページ / 38
MMD24S
MMD24B
TEST PROCEDURES
 
PROCEDURE 
 
LETTER 
COMPONENT TEST
   
unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter 
and ohmmeter.
In  this  service  manual,  the  touch  control  panel  assembly  is  divided  into  three  units,  Control  Unit, 
Keyboard Unit and Power Unit, and troubleshooting by unit replacement is described according to the 
symptoms indicated.
Before testing,
)  Disconnect  the  power  supply  cord,  and  then  disassemble  as  per  "MICROWAVE  DRAWER 
DISASSEMBLY" page  27.
2)  Open the drawer and block it open.
3)  Discharge high voltage capacitor. 
4)  Disconnect the leads to the primary of the power transformer.
5)  Ensure  that  these  leads  remain  isolated  from  other  components  and  oven  chassis  by  using 
insulation tape.
.  Keyboard Unit.
 
NOTE ;
)  Check Keyboard unit connection before replacement.
2)  Reconnect all leads removed from components during testing.
3)  Re-install the covers.
4)  Reconnect the power supply cord after the covers are installed.
5)  Run the oven and check all functions.
 
The following symptoms indicate a defective keyboard unit.
a)  When touching the pads, a certain pad produces no signal at all.
b)  When touching a number pad, two figures or more are displayed.
c)  When touching the pads, sometimes a pad produces no signal.
 
If the Keyboard unit is defective.
)  Disconnect the power supply cord, and then remove covers.
2)  Open the drawer and block it open.
3)  Discharge high voltage capacitor. 
4)  Replace the Keyboard unit.
5)  Reconnect all leads removed from components during testing.
6)  Re-install the covers.
7)  Reconnect the power supply cord after the covers are installed.
8)  Run the oven and check all functions.
2.  Control Unit
 
The following symptoms  indicate a defective control unit.  Before replacing the control unit, perform 
the Keyboard unit test (Procedure B) to determine if control unit is faulty. 
2-  In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light. 
d) The corresponding segments of all digits do not light up; or they continue to light up.
e) Wrong figure appears.
f)  A certain group of indicators do not light up.
g) The figure of all digits flicker.
2-2  Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Clock does not operate properly.
c) Cooking is not possible.
3.  Power Unit or Touch Control Transformer
a)  Fan motor, stirrer motor, oven lamp or electrical parts do not turn on or do not turn off.
b)  Digital display on the control unit does not show anything.
When testing is completed,
)  Disconnect  the  power  supply  cord,  and  then  disassemble  as  per  "MICROWAVE  DRAWER 
DISASSEMBLY" page 27.
2)  Open the drawer and block it open.
3)  Discharge high voltage capacitor. 
 
TOUCH CONTROL PANEL ASSEMBLY TEST
                               The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,