Sharp MMD24B ユーザーズマニュアル

ページ / 38
27
MMD24S
MMD24B
Back cover
Exhaust duct
screws
Top plate
Right side panel
Left side panel
Air cover
Cavity
Fig. 1
.   Before removing Microwave Drawer, take measures to protect    
    the Drawer louver by either removing the louver or by letting  
 
    the louver over hang off flat protected surface (Fig 1)
2.   Open the Drawer to access the 4 mounting screws holding the       
 
  
 unit on to the wall or cabinet opening. (Fig 1).
3.   Close Drawer and carefully pull the unit out from opening and    
    unplug the power supply cord.
4.   Remove top cover. (Fig 2).
5.   Remove air cover from back of unit, then both side panels. (Fig 2).
6.   Remove exhaust duct and back cover. (Fig 2).
NOTE: You now have access to various components for the Drawer.
WARNING: Follow all safety precautions as stated at the beginning of this Service   
                    Manual before proceeding!
Fig. 2
MICROWAVE DRAWER DISASSEMBLY
Louver