Sharp R-8000G ユーザーズマニュアル

ページ / 36
26
A40509,R-8000G O/M
CUSTOM HELP
Custom Help provides 6 features that make using your
oven easy because specific instructions are provided
in the Interactive Display.
O T H E R   C O N V E N I E N T   F E A T U R E S
2. SOUND ON/OFF
If you wish to have the oven operate with no audible
signals, touch CUSTOM HELP 3 times , SET and then
touch STOP/CLEAR.
To cancel and restore the audible signal, touch CUSTOM
HELP 
3 times, SET and then touch START.
1. REFRESH CYCLE
Use the Refresh Cycle to
Condition the heaters before using the oven the first time.
Remove any objectionable odor.
Follow the procedure below. The oven temperature will
be maintained at 450 °F when the Refresh Cycle oper-
ates.
P R O C E D U R E
1
Touch CUSTOM HELP pad
twice.
3
Touch START pad.
2
Touch SET pad.
x 2
NOTE:
1. Remove the turntable from the oven before the
Refresh Cycle. No food should be in the oven.
2. The Refresh Cycle is 30 minutes.
3. During the Refresh Cycle some smoke and odor
may occur. Open a window or use the ventilation
fan in the room.
Caution
:
The oven door, outer cabinet and oven cavity will
be hot.
3. COUNTER CHECK
You can check the total number of times the oven  was
used as well as the times each memory was used.
* Suppose you want to know the total number of times.
P R O C E D U R E
1
Touch CUSTOM HELP pad
4 times.
3
Touch SET pad for the
total number.
2
Touch SET pad.
x 4
NOTE:
1. To check the times each memory was used, touch
desired memory number at step 3.
2. You can coninue to check the times in other memories
by pressing the desired memory number after step 3.
3. The counter can count the times to 999999 for the
total times and 9999 for each memory, and then it
will return to 0.
4. To complete counter check, press STOP/CLEAR
pad after step 3.
Touch desired pad.
4. COUNTER CLEAR
You can clear total use time and total memory uses.
P R O C E D U R E
1
Touch CUSTOM HELP pad
5 times.
3
2
Touch SET pad.
x 5
4
Touch SET pad to clear
the times.
* Suppose you want to clear the total use times.
Clear the total number
Touch SET pad for total
number.
Touch desired pad
NOTE:
1. To clear memory use times, touch desired
memory number at step 3.
2. You can continue to clear the times in other memories
by repeating step 3 and step 4.
3. To complete counter clear, press STOP/CLEAR
pad after step 4.
R-8000G P.25-
03.9.24, 11:22 AM
26