Instructions for the installer
 
 
22
 
2.  INSTALLATION OF THE OVEN 
 
 
 
The oven must be set up on a perfectly flat surface and left standing 
free. Make sure to allow enough room at the back for easy access to the 
terminal strip for connection of the power cable to mains. 
Installation must be carried out by a 
qualified technician in compliance 
with applicable regulations in force. 
 
 
 
2.1 Electrical connection 
 
Make sure that the power line voltage matches the specifications 
indicated on the rating plate located to the rear of the oven. This rating 
plate must never be removed.
 
 
 
 
The connection terminals are 
located at the rear of the 
appliance. For electrical 
connections see following 
diagram. For access to the 
terminal board, remove the 
door located at the back of 
the oven. 
 
 
 
 
 
 
For operation on 380-415V3N
: use an 
H07RN-F-type five-core cable (5 x 1.5 mm
2
).
 
 
 
 
 
For operation on 220-240V
: use an 
H07RN-F-type three-core cable (3 x 4 mm
2
).
 
 
 
The cable end to be connected to the 
appliance must be provided with an ground 
wire (yellow-green) at least 20 mm longer.