SEQUENCE OF OPERATIONS 
IMPINGER II ADVANTAGE 
SERIAL NUMBER 2038616 AND ABOVE 
(OVENS WITH PUSH BUTTON CONTROLS) 
 
MODEL 1154-000-EA   
NAT. GAS 
230VAC 
50 HZ.   
1 PHASE 
MODEL 1155-000-EA   
LP GAS 
230VAC 
50 HZ.   
1 PHASE 
 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a three conductor service. 
CONTROL BOX AUTO 
COOL DOWN 
When the temperature in the control box reaches 120
°F ± 3°F (48.9°C ± 1.7°C), 
the cooling fan thermostat will switch power to the control box cooling fan. The 
thermostat will interrupt power to the cooling fan when the control box temperature 
falls to 100
°F ± 3°F (37.8°C ± 1.7°C). 
MAIN FAN CIRCUIT 
Power is permanently supplied, through a 10 amp oven fuse, through a normally 
closed control box hi-limit thermostat (opens at 140
°F, 60°C), to the normally open 
double pole oven fan switch and to the cooling fan. Closing the oven fan switch 
supplies line voltage to the main fan motor. Closing the main fan switch also 
supplies voltage to the cooling fan, the primary of the control transformer, the 
conveyor motor, and the burner system. 
BURNER CIRCUIT 
Closing the oven fan switch supplies line voltage through the normally open gas 
pressure switch (located in the gas valve and closed when gas pressure is 
present), through the normally open air pressure switch (closed by the air pressure 
from the main fan), through the normally closed oven cavity hi-limit thermostat 
(opens at 662
°F, 350°C), and to the ignition control. 
IGNITION CONTROL 
The ignition control switches line voltage to the combustion blower motor. The 
combustion air pressure switch switches from normally closed to normally open 
upon sensing air pressure in the burner housing. After a pre-purge period of 
between 30 and 60 seconds, the spark generator is energized, the main gas valve 
and the burner pilot light are energized, and ignition should now occur. 
TEMPERATURE CONTROL 
Closing the oven fan switch supplies line voltage to the primary of the control 
transformer. Secondary voltage, 24VAC, is supplied to the oven control. The oven 
control is set to desired temperature. The thermocouple will provide varying 
millivolts to the oven control. The oven control supplies line voltage to the 
temperature regulation valve at intermittent intervals to maintain the desired 
temperature. The display on the oven control will indicate when the temperature 
regulation valve is energized. 
NOTE: The display also indicates oven temperature. 
CONVEYOR DRIVE 
Closing the oven fan switch supplies line voltage to the conveyor motor and to the 
primary of the control transformer. Secondary voltage, 24VAC, is supplied to the 
oven control. Setting the oven control to the desired time outputs voltage, through 
a reversing switch, to the conveyor motor. 
NOTE: The conveyor system uses a hall effect sensor and magnet to prove 
operation of the conveyor motor. If the conveyor motor is not running, “BELT JAM” 
is indicated on the display.