Lincoln 1456-V00-V プリント

ページ / 2
Global
Global
Gas Supply Pressure Recommendations:
Gas Type
Supply (Inlet) Pressure (mbar)
Recommended  
Minimum  
Gas Pipe Size
Natural
9-14” WC (2.2 kPA / 22.4 mbar - 3.5 kPa / 34.9 mbar)
2”  (51 mm)
LP
11-14”  WC (2.7 kPa / 27.36 mbar - 3.5 kPa / 34.9 mbar)
2”  (51 mm)
*Gas supply pressures are dependent on local gas type and on all applicable local codes.  Agency approved flexible 
connection to each oven must be minimum ¾” (19 mm) NPT and length must not exceed six (6) feet (1829 mm).
Electrical Service:
Each oven deck requires voltage, phase and hertz as indicated by model number.  Neutral must be grounded 
at electrical service and receptacle properly polarized.  Gas 120V units have a cord with NEMA 5-15 plug.  
All other models have terminal block connections.  It is recommended that a separate circuit breaker be 
provided for each oven deck.
Recommended Minimum Clearances:
Rear of oven to combustible surface: 6” (152 mm). Clearance on right side from other cooking equipment: 24” 
(610 mm).  Clearance required to remove conveyor for cleaning: 11’ (3553 mm).
Warranty:
All new impinger
®
 ovens installed in the United States and Canada come with a one (1) year parts and labor 
warranty starting from the date of start-up/check-out.  All ovens installed in locations other than in the US 
and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out.  Start-up/check-out must occur within 24 months of date of manufacture.
General Information:
All 1600 Models
Length
Depth
Height 
Single
Height 
Double Stacked
78” 
(1981 mm)
58” 
(1473 mm)
52” 
(1321 mm)
64 ⁵/₈” 
(1641 mm)
Model  
Number
Agency
Utility
Input Rate
Voltage
Hertz
Phase
Supply
1433-000-E
NSF/CE
Natural
120,000 BTU/Hr.
32.5 kW
126.6 MJ
230
50
1
3
1450-000-U
NSF/CSA
Natural
120
60
1
3
1456-V00-B
AGA/NSF
Natural
240
50
1
3
1434-000-E
NSF/CE
LP
230
50
1
3
1447-000-N
--
LP
220
60
1
3
1451-000-U
NSF/CSA
LP
120
60
1
3
1457-V00-B
AGA/NSF
LP
240
50
1
3
1421-000-E
NSF/CE
Electric
27 kW
400/230
50
3
5
1452-000-U
NSF/UL/CSA
Electric
120/208
60
3
5
1453-000-U
NSF/UL/CSA
Electric
120/240
60
3
5
1454-000-N
NSF/UL/CE
Electric
380Y/220
50
3
5
1455-000-N
NSF/UL/CE
Electric
415Y/240
50
3
5
1458-000-E
NSF/UL/CE
Electric
400
50
3
4
NOTE: Panel setups are added as kit numbers to the end of the model number to complete the oven order; (example: 1450-000-U-K1801 is a 1450-000-U with 
standard setup, left to right.)
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open 
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
Technical Drawings:
NOTE: Specifications subject to change without notification.
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open 
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
1400 S
er
ies  | I
mpinger® I Single B
elt C
on
ve
yor
iz
ed O
ven
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open 
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open 
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN