3
SEQUENCE OF OPERATIONS 
IMPINGER II ADVANTAGE 
SERIAL NUMBER 2038616 AND ABOVE 
(OVENS WITH PUSH BUTTON CONTROLS) 
 
 
 
MODEL 1164-000-EA 
 400/230VAC 
 50HZ. 
 3 
PHASE 
 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a four conductor service. 
Brown conductor is hot. 
Black conductor is hot. 
Black conductor is hot. 
Green conductor is ground. 
MAIN FAN CIRCUIT 
Power is permanently supplied, through the 10 amp oven fuse, through the 
normally closed control box hi-limit thermostat (opens at 140
°F, 60°C), to the 
normally open oven fan switch. Power is also supplied to the normally open 
cooling fan thermostat. Closing the oven fan switch supplies line voltage to the 
main fan motor, the cooling fan, the primary of the control transformer and to 
the oven control. 
HEAT CIRCUIT 
Closing the oven fan switch supplies line voltage, through the normally open air 
pressure switch (closed by air pressure from the main fan) to the oven control. 
Line voltage is also supplied to the primary of the control transformer. Secondary 
voltage, 24VAC, is supplied to the oven control. The oven control is set to desired 
temperature. The thermocouple will provide varying millivolts to the oven control. 
The oven control supplies line voltage to the coil of the contactor at intermittent 
intervals to maintain the desired temperature. The display on the oven control will 
indicate when the contactor is energized. 
NOTE: The display also indicates oven temperature. 
CONVEYOR CONTROL 
Closing the oven fan switch supplies line voltage to the conveyor motor and to the 
primary of the control transformer. Secondary voltage, 24VAC, is supplied to the 
oven control. Setting the oven control to the desired time outputs voltage, through 
a reversing switch, to the conveyor motor. 
NOTE: The conveyor system uses a hall effect sensor and magnet to prove 
operation of the conveyor motor. If the conveyor motor is not running, “BELT 
JAM” is indicated on the display.