Maytag AOES3030 ユーザーズマニュアル

ページ / 47
Component Testing Information 
 
!
WARNING
 
To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless  
testing requires it. 
 
 
16021875   Rev. 0 
©2003 Maytag Appliances Company
 
12 
 
Illustration Component 
Test 
Procedure 
Results 
ERC4800 Controlled 
Child lock out 
This is a safety feature that can be 
used to prevent children from 
accidentally programming the oven. It 
disables the electronic oven control. 
Press and hold Bake and Cook Time 
for 10 seconds. “OFF” will display 
where the temperature normally 
appears. 
To reactivate the control, press and 
hold Bake and Cook Time for 10 
seconds. Child lockout features must 
be reset after a power failure. 
 
 
E17
E16
E11
E10
E13
E12
E18
E3
E2
E14
E15
E6
E7
E8
E9
E4
E5
E19
K10
K11
K4
K2
K5
K6
K3
K1
Oven
Light
Panel
Light
Bake
Broil
  Conv.
Element
Door
Lock
Conv.
 Fan
Double
Line Brk
E1
 
 
Relay board 
Listen for relay to actuate. 
Verify input and output power. 
If relay does not actuate, verify power to 
relay. 
 
 
ERC/Adapter board 
assembly 
F1 - Control malfuction. 
Replace ERC. 
 
Field Selectable Options 
Standard:  The standard setup is 8. This is a 12 hour type of clock, 60 Hz line frequency and an oven with a 
convection fan. 
Clock Time Format 
12 or 24 hour format 
The time of day and the stop time can be displayed in either a 12 or 24 hour format. The control will come in a 12 
hour format and can be changed to a 24 hour format from the front control panel. 
Clock Time Base 
60 or 50 Hz input line frequency 
This is a time reference for the clock, timer, and internal timing of the control. The control will select the frequency 
automatically when the control is powered up. 
Selecting Options 
In order to select the field selectable options, Press and hold the CLOCK pad on power up of the control. To change 
the options press one of the slew pads until the desired option appears and in approximately 9 seconds the control 
will change to the normal operation or once selected press the CANCEL pad. The right time digit will indicate the 
current options selected as listed in the table below. (Standard setting is 8.) 
Code Number 
24 Hour Clock 
50 Hz 
No Convection Fan 
 
 
 
9 X 
 
 
 
 
r X X 
 
 
 
d X 
 
 
 
X X 
Blank X  X 
X = indicates Selected 
  = indicates Not Selected