Instructions for the installer
 
 
116
 
2.2 Mounting the oven 
The oven is designed for mounting into any piece of furniture as long as 
heat-resistant. Proceed according to the dimensions shown in Figures 1
2 and 3. For installing under a work top, follow the dimensions given in 
Figure 1-3. For installing under a work top with combined heating plates, 
ensure a minimum clearance from any side walls of at least 110 mm as 
shown in Figure 1.  
For installing in a column, follow the dimensions given in Figure 1-2 
allowing for a clearance of 80 to 90 mm at the top and sides of the 
column. Tighten the four screws A inside the frame to secure (Fig. 1). 
For installing beneath a non-integrated top, allow for a rear and bottom 
clearance as shown in Figure 1 (ref. B). See relevant instructions for 
fitting and securing the cook top.