Hobart HIC4 ユーザーズマニュアル
– 16 –
MAINTENANCE
WARNING: THE DELI CASE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE DELI CASE.
CLEANING OR SERVICING THE DELI CASE.
WARNING: DISCONNECT ELECTRICAL SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT BEFORE PERFORMING ANY
MAINTENANCE.
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT BEFORE PERFORMING ANY
MAINTENANCE.
REPLACING THE OVERHEAD HEAT LAMPS
WARNING: THE HEAT LAMPS ARE HOT. THE LAMPS MUST BE ALLOWED TO COOL BEFORE
REPLACING.
REPLACING.
Full Service
Unscrew old heat lamp bulb(s) and replace with Cov-R-Guard Opaque Coated bulb(s) rated 130 watt,
120 volt, either:
120 volt, either:
General Electric part number 150R/FL130WM/CVG; or
General Electric part number 120R40FL/STGPQ6.
Self-Service Cases, Self-Service Portion of Case or Two Tier Cases
Unscrew old heat lamp bulb(s) and replace with same type infrared bulb rated 250 watt, 120 volt, either:
Prism part number BR40-CL/250 (Clear Non-Cover Guard Coated)*; or
General Electric part number 250R40/1/CVG (Clear Cover Guard Coated)**.
*
Factory Standard.
** Optional.
REPLACING THE HALOGEN LAMPS
WARNING: THE HALOGEN LAMPS ARE HOT. THE LAMPS MUST BE ALLOWED TO COOL
BEFORE REPLACING.
BEFORE REPLACING.
Unscrew old halogen lamp(s). Use a soft cloth to handle the bulbs. Human contact will reduce life of
bulbs. Replace with clear, standard base bulb rated 75 watt, 120 volt:
bulbs. Replace with clear, standard base bulb rated 75 watt, 120 volt:
Abco part number 04812 (Westinghouse type JDD).
SERVICE
Contact your local Hobart Service Office for any repairs or adjustments needed on this equipment.
FORM 33798 Rev. A (Sept. 2001)