MAINTENANCE
WARNING:  THE DELI CASE AND ITS PARTS ARE HOT.  USE CARE WHEN OPERATING,
CLEANING OR SERVICING THE DELI CASE.
WARNING:  DISCONNECT ELECTRICAL SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT BEFORE PERFORMING ANY
MAINTENANCE.
REPLACING THE OVERHEAD HEAT LAMPS
WARNING: THE HEAT LAMPS ARE HOT.  THE LAMPS MUST BE ALLOWED TO COOL BEFORE
REPLACING.
Full Service
Unscrew old heat lamp bulb(s) and replace with Cov-R-Guard Opaque Coated bulb(s) rated 130 watt,
120 volt, either:
General Electric part number 150R/FL130WM/CVG; or
General Electric part number 120R40FL/STGPQ6.
Self-Service Cases, Self-Service Portion of Case or Two Tier Cases
Unscrew old heat lamp bulb(s) and replace with same type infrared bulb rated  250 watt, 120 volt, either:
Prism part number BR40-CL/250 (Clear Non-Cover Guard Coated)*; or
General Electric part number 250R40/1/CVG (Clear Cover Guard Coated)**.
*
Factory Standard.
** Optional.
REPLACING THE HALOGEN LAMPS
WARNING: THE HALOGEN LAMPS ARE HOT.  THE LAMPS MUST BE ALLOWED TO COOL
BEFORE REPLACING.
Unscrew old halogen lamp(s).  Use a soft cloth to handle the bulbs.  Human contact will reduce life of
bulbs.  Replace with clear, standard base bulb rated 75 watt, 120 volt:
Abco part number 04812 (Westinghouse type JDD).
SERVICE
Contact your local Hobart Service Office for any repairs or adjustments needed on this equipment.
FORM 33798 Rev. A (Sept. 2001)