36" (91.4 cm) Cooktop
 
Cabinet Dimensions
NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
A minimum side clearance of 6" (15.2 cm) is recommended 
between side of cooktop and side wall for maximum 
ventilation performance.
A minimum clearance of 
2" (5.1 cm) is recommended 
between the motor/blower and cabinet for proper cooling. A 
6" (15.2 cm) clearance is recommended for servicing access.
A.
30
" (76.2 cm)
B. 12
¹⁵⁄₁₆
" (32.9 cm) centerline of 
cooktop to centerline of gas 
manifold pipe
C. 4" (10.2 cm)
D. 6
¹⁹⁄₃₂
" (16.8 cm)
E. 18
⁷⁄₁₆
" (46.8 cm)
F. 1
¹¹⁄₁₆
" (4.3 cm) recommended 
minimum cabinet to motor 
clearance
G. 12
¹⁄₂
" (31.8 cm)
H. 14" (35.6 cm)
I. 28¼" (71.4 cm)
A. 21½" (54.6 cm)
B. 19
¹¹⁄₁₆
" (50.0 cm)
C. Model/serial rating plate location
A. 3
6
" (91.4 cm)
B. 15¾" (40.0 cm) centerline of 
cooktop to centerline of gas 
manifold pipe
C. 4" (10.2 cm)
D. 6
¹⁹⁄₃₂
" (16.8 cm)
E. 18
⁷⁄₁₆
" (46.8 cm)
F. 10
³⁄₈
" (26.4 cm) 
recommended minimum 
cabinet to motor clearance
G. 12
¹⁄₂
" (31.8 cm)
H. 1
3
" (33.0 cm)
I. 34
³⁄₈
" (87.3 cm)
A
B
C
D
E
F
G
H
I
C
A
B
A
B
D
C
E
F
I
G
H
A. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24" [61.0 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than ¼" [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
E. 2
¹⁄₈
" (5.4 cm)
F. 19
¹⁵⁄₁₆
" (50.6 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of 
cabinet
J. 28
⁵⁄₈
" (72.7 cm) on 30" (76.2 cm) models
34¾" (88.3 cm) on 36" (91.4 cm) models
K. 6" (15.2 cm) minimum distance to nearest left and right side 
combustible surface above cooktop
L. 2" (5.1 cm) minimum clearance between back wall and countertop
M. Gas line opening - Wall: anywhere 6" (15.2 cm) below underside of 
countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall 
is recommended.
N. 25" (63.5 cm) depth of countertop
B
D
A
E
F
H
I
K
L
K
M
M
C
G
N
J