INSTALLATION INSTRUCTIONS
62.9582.01_UL
Page 7
4.
ELECTRICAL CONNECTION
Each appliance is accompanied by a complete connection and 
wiring diagram enclosed. This contains full details of the 
technical specifications (electrical rating, voltage, amperage 
etc.)
Check and ensure that the mains voltage agrees with the 
voltage given on the specification plate.
N.B.:
The corresponding arrangements must be made on-site for 
the earthing connection and fuse protection for the 
appliances.
The appliance must be connected to a potential 
equalization system 
 with a minimum conductor cross-
section of 10 mm². The correspondingly marked 
connection terminal must be used for this purpose. When 
set up in block configuration, all appliances must be 
interconnected as potential equalization.
The appliance is designed for connection to fixed lines. If 
the appliance is fitted directly to a masonry plinth without 
an appliance plinth, the supply must be located at the 
prescribed place. In this case, the protecting tube may not 
protrude from the plinth. If a CNS base is used, the 
protecting tube may not protrude more than 10 cm from the 
floor.
After installation, the shock-hazard protection for live and 
functionally insulated parts must be secured.
An isolating device working on all poles and with a 
minimum contact opening of 3 mm must be provided on 
site.
When faulty-current circuit breakers are used, ones for a 
rated tripping current of 30 mA should be used.
When using a faulty current-operated circuit-breaker (in the 
case of an existing circuit-breaker and for new installations) 
only a one pulse-current sensitive faulty current-operated 
circuit-breaker may be connected in series in conjunction 
with these appliances. 
4.1
CONNECTION TERMINALS
Power is taken from a ready-installed electric cable which 
protrudes 1.5 m from the floor or the wall.
The connection terminals for the appliance are located behind 
the front right-hand cover (B). In order to connect the 
appliance, the front panel must be removed (see Chapter 2.1 
on page 6).
Power cable connection as per the electrical diagram.
The terminal screws on the range frame are marked as 
follows:
Earth wire 
Potential equalization 
Additional terminals for power optimizing systems (EO/SI) or 
potential-free contacts (PK) for the external monitoring of the 
appliance are available as options. The connections are made 
as per the electrical diagram.
4.2
CONNECTION TO THE POTENTIAL 
EQUALIZATION SYSTEM
The appliance is to be connected to a potential equalization 
system with a minimum conductor cross-section of 10 mm². 
Use the appropriately marked terminal studs for this purpose 
(EN 60 335). The connection consists of an M6 threaded bolt 
and is located on the frame of the appliance.
Connection as per sketch.
A = Mains connection
G = Appliance outgoing 
 
section
 Fig.9
Connection terminals
 1 Cable shoe * 6 mm
  2 Nut  M  6
 3 Spring washer M 6
 4 Washer M 6
 Fig.10 Connection to the potential equalization system