  If the power cable is replaced, the wire section on the new cable must 
not be less than 1.5 mm
2
 (3 x 1.5 cable), keeping in mind that the end 
to be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which 
has a maximum temperature of 90°C. This must be done by a 
specialised technician, who must connect the cooker to the electricity 
supply according to the diagram shown here. 
L = brown 
N = blue 
 = yellow-green. 
 
   
 
 
2.2  Ventilation requirements 
 
   
 
  The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 
1989. 
1.  All rooms require an opening window or equivalent, and some rooms will require a permanent 
vent as well. 
2.  For room volumes up to 5 m
3
 an air vent of 100 cm
2
 is required. 
3.  If the room has a door that opens directly to the outside, and the room exceeds 1 m
3
 no air vent 
is required. 
4.  For room volumes between 5 m
3
 and 10 m
3
 an air vent of 50 cm
2
 is required. 
5.  If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be 
consulted to determine the air vent requirements. 
6.  This appliance must not be installed in a bed sitting room of less than 20 m
3
 or in a bathroom or 
shower room.Windows and permanent vents should therefore not be blocked or removed without 
first consulting a Corgi gas installer. 
Failure to install appliances correctly is dangerous and could lead to prosecution. 
 
   
 
 
2.3  Connecting to natural and LPG gas 
(Please see connection diagram)
 
 
 
 
 
 Make the connection to the appliance using flexible bayonet style hose in 
accordance to B.S. 669. The hose connection at the rear of the appliance has a 
½” BSP internal thread. Please use seal C between the flexible connection L and 
the appliance supply tube B. When making the connection, make sure that no 
stress of any kind is applied to the cooker and that the hose does not touch any 
sharp edges. 
If connecting to LPG the bayonet hose must have red bands on it.