Lightolier 8292CY プリント

ページ / 2
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:8292CY
A0400    
Page 1 of 2
INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF PowerArc
CANOPY FIXTURE
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA  02720
®
INSTRUCTIONS FOR ATTACHING PowerArc CANOPY FIXTURE TO
WALL OR CEILING MOUNTED JUNCTION BOX (see FIG’s 1 & 2):
1. Turn off power at fuse box before installation.
2. Using the appropriate slots in CROSS-BAR, secure the CROSS-BAR
ASSEMBLY to the J-BOX with the J-BOX SCREWS.
NOTE: To lock HORIZONTAL ROTATION, install the ROTATION SCREW
into the desired position hole in the CROSS-BAR and tighten (see Fig 2).
These holes are located every 45˚. This step is necessary only if hori-
zontal locking is desired. Otherwise, rotation screw can be removed.
3. Rotate the HEAD of fixture 90˚ for easier access to the J-BOX. 
4. Feed both FIXTURE LEADS through the EYELET in the center of the
CROSS-BAR ASSEMBLY and back out of the J-BOX.
5. Move the FIXTURE MOUNTING BRACKET in direction “A”, lining up
the 2 top slots on the bracket with the 2 top FIXTURE MOUNTING
SCREWS. Once the 2 top slots are inserted, slide the fixture in 
direction “B” until all 4 slots on the FIXTURE MOUNTING BRACKET
engage into all 4 FIXTURE MOUNTING SCREWS. Tighten all 4 
FIXTURE MOUNTING SCREWS.
6.  Make wiring connections using WIRE NUTS (local hardware item):
• When installing 120V fixture (8292WECY), black  FIXTURE LEAD to 
hot (black) SUPPLY LEAD, white FIXTURE LEAD to neutral (white) 
SUPPLY LEAD, and FIXTURE GROUND LEAD to SUPPLY 
ground.
• When installing 277V fixture (8292WECY2),red FIXTURE LEAD to 
hot SUPPLY LEAD, white FIXTURE LEAD to neutral (white)
SUPPLY LEAD, and FIXTURE GROUND LEAD to SUPPLY ground .
Once connections have been made, push wires and connections 
into the J-BOX.
7.  Push CANOPY against MOUNTING SURFACE to cover J-BOX.
AIMING ADJUSTMENTS (see Fig 3):
CAUTION:  ALLOW TIME FOR FIXTURE TO COOL
BEFORE MAKING ANY ADJUSTMENTS!
Fixture has both a VERTICAL and a HORIZONTAL ROTATION. It is
equipped with stops for both rotations (DO NOT FORCE FIXTURE PAST
STOPS. DOING SO MAY CAUSE ELECTRICAL HAZARD).
For Precise AIMING, rotate Head of fixture and line up desired angle
on the AIMING INDICATOR with the INDICATOR TAB.
CAUTION: IN ACCORDANCE WITH LAMP MANUFACTURES INSTRUC-
TIONS, DO NOT INSTALL PowerArc ON WALL IN A MANNER THAT
WOULD POSITION THE LAMP MORE THAN 45˚ AWAY FROM THE
HORIZONTAL PLANE (SEE FIG.4).
INSTRUCTIONS FOR UNLOCKING THE HORIZONTAL ROTATION, ONCE THE
PowerArc CANOPY FIXTURE IS FULLY INSTALLED (see FIG’s 1, 2 & 3):
1. Turn off power at fuse box before making adjustments.
2. Rotate the HEAD of fixture 90° for easier access to the J-BOX.
3. Reverse steps 7 and 5 from the fixture mounting instructions above.
4. Uninstall the ROTATION SCREW from the CROSS-BAR ASSEMBLY.
5. Repeat steps 5 and 7 from the fixture mounting instructions above.
J-BOX
CROSS-BAR
FIXTURE GROUND LEAD
CANOPY
J-BOX SCREWS
CROSS-BAR 
ASSEMBLY
FIXTURE 
MOUNTING
SCREWS (4)
FIXTURE 
MOUNTING
SCREWS (4)
ROTATION
SCREW
EYELET
SUPPLY LEADS
MOUNTING 
SURFACE
FIG. 3
FIG. 2
FIG. 1
FIG. 4
FIXTURE 
MOUNTING
BRACKET
WIRE NUTS
FIXTURE LEADS
GROUND
WIRE
HEAD
HEAD
A
B
90˚ VERTICAL
HEAD ROTATION
INDICATOR TAB
VERTICAL AIMING
ANGLE INDICATOR
350˚ HORIZONTAL
ROTATION
TOP SLOTS