Xerox Phaser 5500 Drum Cartridge 113R00685 プリント
製品コード
113R00685
Hardware Issue
SB 669
Page
1 of 4
Copyright © 2003 Xerox Corporation. All rights reserved. XEROX®, the stylized X®, and Phaser®
trademarks of Xerox Corporation in the United States and/or other countries.
trademarks of Xerox Corporation in the United States and/or other countries.
X
erox
O
ffice
G
roup
Phaser 5500
(Europe Only) Dual Model PIN Requirements
Following Repair
Following Repair
INFORMATION
The following scenarios describe when the 4-digit PIN number will
need to be re-entered into a metered device. If the customer does not
know the 4 digit PIN, you will need to contact Xerox Customer
Support and request the PIN. You will need to provide the serial
number of the metered device.
need to be re-entered into a metered device. If the customer does not
know the 4 digit PIN, you will need to contact Xerox Customer
Support and request the PIN. You will need to provide the serial
number of the metered device.
Catastrophic
Engine Board
Failure
(MCU)
Engine Board
Failure
(MCU)
• Replace MCU
*
board
• MCU board will not have any of the settings from
the previous board – i.e., registration values, etc.
• Need to set the MCU board into PagePack mode
• Enter Service Diagnostics Mode (technician
has access, customer does not)
• In Service Diagnostics, select Menu “IP
NVRAM” then Factory NVRAM Reset
(password “4370”) perform reset
(password “4370”) perform reset
• Enter the Hidden Service Menu (technician has
access, customer does not)
Select “Service Tools Menu” then press the up
key then down key releases keys.
Select “Service Tools Menu” then press the up
key then down key releases keys.
• “Enable Metered Toner” menu will appear,
press OK.
• Front panel prompts for PIN, enter
customer PIN
• MCU will NOT have the machine serial number
loaded
• Technician needs to load the serial number via
snippet or CWIS
SB 669
04 March 2005
Service Bulletin
Phaser 5500
Xerox Office Group Service Bulletin
SB 669
Page 2 of 4
Non-catastrophic
Engine Board
Failure
(MCU)
Engine Board
Failure
(MCU)
• Print a Configuration page
• Enter Service Diagnostics and perform the “Engine
Logic Board Replacement” procedure in Service
Diagnostics. (Save from Engine Board)
Diagnostics. (Save from Engine Board)
• Power printer off and Replace MCU
*
board
• Enter Service Diagnostics and perform the “Engine
Logic Board Replacement” procedure in Service
Diagnostics. (Restore to Engine Board)
• Verify the restore command worked properly by
Diagnostics. (Restore to Engine Board)
• Verify the restore command worked properly by
printing a Configuration page and confirming
the printer serial number and page count
the printer serial number and page count
• If the restore command was unsuccessful, then
this procedure will be equivalent to
the “catastrophic MCU failure” scenario
the “catastrophic MCU failure” scenario
• IP controller knows PIN was already
entered
Catastrophic
IP controller
failure
IP controller
failure
• Replace IP controller
*
board
• New IP controller will read machine serial number
and PagePack enablement from MCU board Front
panel prompts for PIN
panel prompts for PIN
Catastrophic
Engine Board
failure (MCU) and
IP Controller
failure
Engine Board
failure (MCU) and
IP Controller
failure
• Replace MCU
*
and IP controller
*
boards
• MCU board will not have any of the settings from
the previous board – i.e., registration values, etc.
including serial number
• Technician needs to load the serial number via
including serial number
• Technician needs to load the serial number via
snippet or CWIS
• To enable the printer to be PagePack, technician
needs to access the Hidden Service Menu and
select the item “Enable Metered Toner”
(refer to Catastrophic Engine Board failure for
menu entry) Will prompt immediately for PIN,
enter customer PIN
select the item “Enable Metered Toner”
(refer to Catastrophic Engine Board failure for
menu entry) Will prompt immediately for PIN,
enter customer PIN
Firmware
Upgrade
Upgrade
No effect
*
The Engine Board (MCU) and IP controller board spares will
have the PagePack capable firmware loaded. Engine board version
11.30.01 (or greater) and IP controller version PS G.02.06 or greater.
11.30.01 (or greater) and IP controller version PS G.02.06 or greater.