Troubleshooting 
6
309739
Troubleshooting
Problem
Cause
Solution
Gun fails to dispense when trigger is 
actuated
Material lodged in nozzle
Follow Pressure Relief Procedure
page 5. Clear nozzle of blockage.
Material supply, hose, passages, 
clogged
Check material supply settings, 
hoses, etc. for proper material supply.
Verify integrity of trigger pin through 
yoke. Repair or replace cartridge 
assembly as necessary.
Gun fails to dispense when trigger is 
engaged
Tension of trigger needs adjustment
Check spring tension adjustment at 
rear of gun. Spring tension should be 
adjusted to allow approximately 1/32 
in. of free play on trigger.
Verify integrity of trigger pin through 
yoke. Repair or replace cartridge 
assembly as necessary.
Needle and seat adapter loose or 
worn
Check that seat adapter is tightened 
firmly and flush to gun body.
Needle and seat adapter worn. 
Replace components as necessary.
Seal leakage
Packing adjustment nut not snug
Follow Pressure Relief Procedure
page 5. Tighten packing adjustment 
nut.
Worn seals and packings 
Rebuild gun as necessary.
Material leaks from gun inlet swivel
Worn seals
Replace seals.