Cleanup
310892F
25
9.
Hold gun against mate-
rial pail. Take trigger 
safety OFF. Turn pres-
sure control up until 
motor begins to drive 
pump. Trigger gun until 
flushing fluid appears.
10. Move gun to flushing 
pail, hold gun against 
pail, trigger gun to thor-
oughly flush system. 
Release trigger and put 
trigger safety ON. 
11. Turn prime valve down 
and allow flushing fluid 
to circulate for approxi-
mately 20 seconds to 
clean drain tube.
12. Raise siphon tube above 
flushing fluid and run 
sprayer for 15 to 30 sec-
onds to drain fluid. Turn 
pump switch OFF. Turn 
engine OFF.
-!4%2)!,
ti5890a
FLUSH
ti5981a
20 SEC
ti5838a
-!4%2)!,
&,53(
ti5822a
/&&
ti5827b
OFF
/&&
/.