Indoor unit malfunction
Display code
Float switch or water motor abnormal
E0
Outdoor unit abnormal
E1
Setting running mode is different with outdoor
running mode
E2
Liquid temperature sensor is abnormal
E3
Gas    temperature sensor is abnormal
E4
The communication between  indoor 846 chip and
communication chip is  abnormal
E5
The communication with electronic expansion  box
is abnormal
E7
The communication between the wire remote
controller and indoor unit control board is    abnormal
E8
The communication between indoor and outdoor unit
is abnormal
E9
Water temp. sensor is abnormal
EB
Outdoor unit malfunction
LED flashing times
Outdoor unit defrost temp. sensor is abnormal
flashing once
Outdoor unit environment temp. sensor is abnormal
flashing twice
Outdoor unit suction temp. sensor is abnormal
flashing 3 times
Outdoor unit discharge temp. sensor is abnormal
flashing 4times
Outdoor unit AC over-current protection
flashing 6times
Outdoor unit DC voltage is insufficient protection
flashing 7times
IPM  protection
flashing 9times
Outdoor unit EEPROM abnormal
flashing 10times
Compressor Discharge temperature overheat
protection
flashing 11times
The communication between outdoor unit 857 and
communication  chip is  abnormal
flashing 12times
Outdoor unit system over-high pressure protection
flashing 13 times
Indoor unit malfunction display code
Outdoor unit malfunction display code
  (When the wire remote controller display E1,can check the indoor unit control board
LED1 or the outdoor unit control board LED1 Outdoor unit control board LED
(ALARMA or ALARMB)).
Malfunction