Auto LUN XP for the XP12000/XP10000
When you try Auto LUN XP migrations or migration cancellations using RAID Manager, EX_CMDRJE 
might appear and the command might be refused, depending on the condition in the disk controller. 
 shows error codes, causes, and solutions for this case.
Table 13
Errors during Auto LUN XP migrations or migration cancellations using RAID Manager
Error code
Cause
Solution
2051
Migration target volume is being used with LUN 
Security XP Extension.
Release the volume from LUN Security XP 
Extension, and perform the volume migration.
2055
Migration target volume is being used with 
Continuous Access XP Journal.
Release the volume from Continuous Access XP 
Journal, and perform the volume migration.
2056
Migration source volume is being used with 
Continuous Access XP Journal.
Release the volume from Continuous Access XP 
Journal, and perform the volume migration.
2057
VMA setting is different between the migration 
target and source volumes.
Volume migration cannot be executed. Check the 
configuration definition file.
2058
Migration target and source volumes belong to 
the same parity group.
Volume migration cannot be executed. Check the 
configuration definition file.
2301
Auto LUN XP is not installed on the 
XP12000/XP10000.
Install Auto LUN XP, and perform the volume 
migration.
2306
LBA size does not match between the migration 
target and source volumes.
Volume migration cannot be executed. Check the 
configuration definition file.
2309
Maximum number of pairs that can be set in the 
disk array is exceeded.
Reduce the number of pairs set in the disk array, 
and perform the volume migration (see 
2311
Auto LUN XP already reserved the migration 
target volume.
Cancel the Auto LUN XP reservation, and perform 
the volume migration.
2312
Migration source volume is online with the host.
Take the migration source volume off-line from the 
host, and perform the volume migration.
232F
Migration source volume is already specified as 
an Auto LUN XP target volume.
Release the volume from Auto LUN XP, and 
perform the volume migration.
2331
Consider the following causes:
Auto LUN XP already reserved the migration 
source volume.
Number of slots in the migration target and 
source volumes does not match.
Do the following:
1.
Cancel the Auto LUN XP reservation, and 
perform the volume migration.
2.
Volume migration cannot be executed. Check 
the configuration definition file.
2332
You cannot add pair settings any more to the 
migration source volume.
Reduce the number of pair settings of the 
specified volume, and perform the migration (see 
2333
Volume specified by the migration cancellation is 
not a migration source volume.
RAID Manager is trying to perform the migration 
cancellation for a pair that is not migrating. 
Check the configuration definition file.
2336
Emulation type of the migration target and source 
volumes does not match.
Volume migration cannot be executed. Check the 
configuration definition file.
2337
Migration source volume is a Business Copy XP 
leaf volume.
Release the Business Copy XP pair, and perform 
the volume migration.
233B
Migration target volume is a Business Copy XP 
primary volume.
Release the Business Copy XP pair, and perform 
the volume migration.
233C
Migration target volume is a Business Copy XP 
secondary volume.
Release the Business Copy XP pair, and perform 
the volume migration.