Service 
Backplane Assembly 
 
 
 
102 
 
 
 
 
 
 
 
Service
 
Figure 38. SCSI Bus Reset Switch Default Settings 
 
 
Table 23. SCSI Bus Reset Switch Functions 
 
Switch 1: 
Bus B 
Power Detect 
Switch 2: 
Bus B 
Module Detect 
Switch 3: 
Bus A 
Power Detect 
Switch 4: 
Bus A 
Module Detect 
Switch 
Enabled 
(Up, Default): 
SCSI bus B is reset if 
one of these events 
occurs: 
 The power switch is 
cycled. 
 Both power cords 
are unplugged. 
 The input voltage 
limits are exceeded on 
both power supplies. 
 Both power supplies 
shut down. 
SCSI bus B is reset if 
a storage module is 
inserted or removed. 
SCSI bus A is reset if 
one of these events 
occurs: 
 The power switch is 
cycled. 
 Both power cords 
are unplugged. 
 The input voltage 
limits are exceeded on 
both power supplies. 
 Both power supplies 
shut down. 
SCSI bus A is reset if 
a storage module is 
inserted or removed. 
Switch 
Disabled 
(Down): 
SCSI bus B is not 
reset if one of the 
above events occurs. 
SCSI bus B is not 
reset if a storage 
module is inserted or 
removed. 
SCSI bus A is not 
reset if one of the 
above events occurs. 
SCSI bus A is not 
reset if a storage 
module is inserted or 
removed.