HP (Hewlett-Packard) SAN Switch ユーザーズマニュアル

ページ / 104
66
NOTE:
The switch will down a port if a rising trigger alarm is not cleared after three consecutive sample 
windows.
Figure 29
Port threshold alarm example
8.
Enter a sample window in seconds. The sample window defines the period of time in which to count 
events.
9.
Repeat steps 3 through 7 for each alarm you want to configure or enable. 
10.
Click 
OK to save all changes.
Paging a switch
You can use the beacon feature to page a switch. The beacon feature causes all Logged-In LEDs to flash, 
making it easier to recognize. Select 
Switch > Toggle Beacon (check mark shown) to page a switch. Select 
Switch > Toggle Beacon again (check mark removed) to cancel the beacon.
Setting the date/time and enabling NTP client
The Date/Time and Network Time Protocol (NTP) dialog enables you to manually set the date, time, and 
time zone on a switch, or to enable the NTP Client. The NTP client synchronizes the date, time, and time 
zone on the switch with an NTP server. Enabling the NTP client ensures the consistency of date and time 
stamps in alarms and log entries. An Ethernet connection to an NTP server is required. When date/time is 
set or displayed in the firmware, it is displayed based on the time zone configured. However, when 
displayed in the Date/Time dialog, the value is always in local time. The difference between switch and 
workstation times must not exceed 24 hours, or the switch management application can not connect. To set 
the date and time on a switch:
1.
Select a switch in the fabric tree to open the faceplate display.
2.
Select 
Switch > Set Date/Time.
3.
Choose one of the following:
• Enter the year, month, day, time, and time zone in the Switch Date/Time dialog. The new date and 
time take effect immediately. 
• Select a time zone option from the Select Time Zone pull-down list.
• Select the 
NTP Client Enabled option to enable the switch to synchronize its time with an NTP server. 
Enter the IP address of the NTP server. Ethernet connection to NTP server is required.
4.
Click 
OK to save the settings.
                                                                                           
Rising 
trigger
Falling 
trigger
Event 
count
Sample window
Generate falling 
trigger alarm; 
eligibility is reset
Generate rising 
trigger alarm; 
eligibility ends
Generate rising 
trigger alarm; 
eligibility ends