HP (Hewlett-Packard) FC 1GB/2GB SWITCH 16B ユーザーズマニュアル

ページ / 60
HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide
2-9
Installing and Configuring the HP Surestore FC 1Gb/2Gb Switch 16B
2
Note
Allow for 1U space in the rack for every five switches to facilitate cable 
management.
a. Connect the power cable to the FC 16B power supply and to a power outlet. 
b. Turn on the power supply (flip the AC switch to “I”) when ready to supply power to 
the switch. The switch automatically runs POST (power on self-test) each time it is 
turned on.
c. If the FC 16B includes a second power supply, repeat Steps 9a and 9b for the 
remaining power supply.
Note
Do not connect the switch to the network until the IP address is correctly set. 
For instructions on how to set the IP address, see 
Configuring and Connecting the Switch
The following items are required to configure and connect the FC 16B for use in a network 
and fabric:
The FC 16B installed and connected to a power source
Workstation that has a terminal emulator application (such as HyperTerminal)
Serial cable provided with the switch, for connecting the switch to the workstation
An unused IP address
Ethernet cable for connecting the switch to the workstation or to a network containing 
the workstation
SFPs and FC cables, as required to connect the switch to the fabric
To configure the FC 16B and connect it to a fabric:
1. Replace the factory IP address and related information with the IP information provided 
by your network administrator by completing the following steps:
a. Remove the shipping plug from the serial port and insert the serial cable provided 
with the FC 16B.
b. Connect the other end of the serial cable to an RS-232 serial port on the workstation. 
If no RS-232 serial port is available on the workstation, the adapter on the end of the 
serial cable can be removed to use the RJ-45 connector to create a serial connection.
c. Verify that the switch power is on and POST is completed.
d. Disable any serial communication programs running on the workstation.
e. Open a terminal emulator application (such as HyperTerminal on a PC, or TERM in 
a UNIX environment), and configure as follows: