HP (Hewlett-Packard) BMD00022 ユーザーズマニュアル

ページ / 228
 
 
 
Configuration Menu  201  
 
 
RMON alarm configuration 
Command:  /cfg/rmon/alarm <1-65535
[RMON Alarm 1 Menu] 
      oid     - Set MIB oid datasource to monitor 
      intrval - Set alarm interval 
      sample  - Set sample type 
      almtype - Set startup alarm type 
      rlimit  - Set rising threshold 
      flimit  - Set falling threshold 
      revtidx - Set event index to fire on rising threshold crossing 
      fevtidx - Set event index to fire on falling threshold crossing 
      owner   - Set owner for the alarm 
      delete  - Delete this alarm and restore defaults 
      cur     - Display current alarm configuration 
The Alarm RMON group can track rising or falling values for a MIB object. The MIB object must be a 
counter, gauge, integer, or time interval. Each alarm index must correspond to an event index that 
triggers once the alarm threshold is crossed.  
The following table describes the RMON Alarm Menu options.  
Table 185 
 RMON Alarm Menu options
 
Command Description 
oid <1-127 characters
Configures an alarm MIB Object Identifier.  
The alarm OID can have a maximum of 127 characters. 
intrval <1-65535
Configures the time interval over which data is sampled and 
compared with the rising and falling thresholds. 
The range is from 1 to 65535 seconds. The default is 1800 
seconds. 
sample abs|delta
 
Configures the method of sampling the selected variable and 
calculating the value to be compared against the thresholds, 
as follows:  
 
abs—
absolute value, the value of the selected variable is 
compared directly with the thresholds at the end of the 
sampling interval.  
 
delta
—delta value, the value of the selected variable at 
the last sample is subtracted from the current value, and 
the difference compared with the thresholds. 
almtype rising|falling|either
 
Configures the alarm type as rising, falling, or either (rising 
or falling). 
rlimit <-2147483647 to 2147483647
Configures the rising threshold for the sampled statistic. 
When the current sampled value is greater than or equal to 
this threshold, and the value at the last sampling interval was 
less than this threshold, a single event is generated. 
flimit <-2147483647 to 2147483647
Configures the falling threshold for the sampled statistic. 
When the current sampled value is less than or equal to this 
threshold, and the value at the last sampling interval was 
greater than this threshold, a single event is generated.