Cabletron Systems 6E133-25 ユーザーズマニュアル

ページ / 184
Chapter 3: Installation
3-8
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
3.5.2
Connecting UTP Cables to Ports 1 Through 24 of 
the 6E133-25 and 6E123-26
When facing the front panel of the 6E133-25 or 6E123-26, the upper 
RJ21 is the connector for 10BASE-T ports 1 through 12. The lower RJ21 
is for 10BASE-T ports 13 through 24. All 24 ports have internal 
crossovers.
Connect a twisted pair segment to the 6E133-25 and 6E123-26 as follows:
1.
Ensure that the device connected to the other end of the segment is 
powered ON.
2.
If using an RJ21 straight connector, plug it into the appropriate RJ21 
port as shown in 
 or, if using the RJ21 angle adapter 
supplied with the device, insert the RJ21 angle adapter as shown in 
. The RJ21 angle adapter allows the cable to be inserted 
without interfering with the proper attachment of the second 
connector.
.
Figure 3-4
6E133-25 and 6E123-26 Twisted Pair Connection
14
13
9
10
11
12
15
16
17
18
19
20
21
22
23
24
RX (Receive)
LED
207603
Screw
Screw Hole
Screw Hole
Screw
24
13
1