Chapter 3: Installation
3-14
ESX-1320/ESX-1380 Installation Guide
3.7.2
Rackmount Installation
To install the ESX in a 19-inch rack, Cabletron Systems includes an 
accessory kit containing the rackmount brackets, mounting screws for 
attaching the rackmount brackets to the ESX chassis, and a strain-relief 
bracket for cable management. Screws to mount the ESX to the rack rails 
are provided by the user.
Guidelines for the Rackmount Installation
The installation site must be within reach of the network cabling and meet 
the requirements listed below:
An appropriate grounded power receptacle must be located within 
seven feet of the location.
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at 
the installation site with fluctuations of less than 10
°
C per hour.
In order to allow for proper cooling, there must be a two-inch 
clearance on either side and the back of the unit.
Installation
Rack mounting the ESX involves the following:
Attaching the strain-relief bracket 
Rack mounting the ESX (attaching the mounting brackets and 
fastening the ESX to the rack)
Attaching the Strain-Relief Bracket
Attach the strain-relief bracket to the front of the ESX as follows:
1. Locate the strain-relief bracket and four 8-32 x 3/8-inch pan head 
screws in the rackmount kit.
2. Attach the strain-relief bracket to the bottom of the ESX using the four 
Do not use longer screws to attach the strain-relief bracket. 
Longer screws could contact electrical components and cause 
personal injury and/or damage the unit.