ページ / 42
RS900 Family Installation Guide 
 
2.2  Power Supply Wiring and Grounding 
2.2.1  AC Power Supply Wiring and Grounding 
 
AC 
Neutral
AC 
Line/Hot
Surge 
Ground
Chassis 
Ground
 
Figure 4 - Power Supply Inputs 
 
The AC power supply inputs should be connected as follows: 
1.  +/L should be connected to AC Line/Hot. 
2.  -/N should be connected to AC Neutral. 
3.  Surge Ground should be connected to the Chassis Ground via a braided cable or other 
appropriate grounding wire. Surge Ground is used as the ground conductor for all surge 
and transient suppression circuitry internal to the unit. 
4.  Chassis Ground must be connected to the AC ground terminal. 
 
NOTES: 
1.  Equipment must be installed according to the applicable country wiring codes. 
2.  All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases 
where users require the inputs to be isolated from ground, remove the ground braid 
between Surge and Chassis Ground. Note that all line-to-ground transient protection 
circuitry will be disabled. 
 
Page 16 of 42 
© 2008 RuggedCom Inc. All rights reserved. 
 
Rev100