Cabletron Systems 2E43-51R ユーザーズマニュアル

ページ / 168
Port Redirect Function Screen
2E43-51/2E43-51R User’s Guide
5-57
Source Port [
n] (Selectable)
Allows a selected port [n] to be changed to a source port.
Destination Port [
n] (Selectable)
Allows a selected port [n] to be changed to a destination port.
Errors (Toggle)
Allows the user to configure the source ports to either (ON) send errored 
frames to selected destination ports, or (OFF) drop errored frames, and 
send only valid traffic to the destination ports. The default setting of this 
field is ON. To set the Errors field, refer to 
Status (Toggle)
Allows the addition or deletion of source and destination ports selected in 
the Source port [n] and Destination port [n] fields.
5.16.1
Displaying the Source and Destination Entries
There can be more than one Port Redirect Function screen depending on 
the number of port redirect entries. Each screen displays up to 10 port 
redirect entries. If there is more than one screen of redirect entries, the 
NEXT and/or PREVIOUS command displays at the bottom of the screen, 
allowing the user to navigate to either the next or previous screen. 
For example, with three screens of entries, the NEXT command displays 
at the bottom of the first screen. In the second screen, the NEXT and 
PREVIOUS commands display. In the last screen, only the PREVIOUS 
command displays. 
To display the next screen, use the arrow keys to highlight NEXT. Press 
ENTER and the next screen of entries displays.
To display the previous screen, use the arrow keys to highlight 
PREVIOUS. Press ENTER to view the entries in the previous screen.